External Connections
5-3
Ext
ernal Eq
uipm
ent
5
5.2
External Equipment
0
Wired Stations
Connections to Coral IPx 500 system station equipment are established by
cross-connecting the station circuit from the appropriate Coral IPx 500 I/O cable punch
block to the corresponding station wiring punch block.
Table 5-1
lists the various station interface cards available for the Coral IPx 500 system,
the type of station equipment that the card supports, and the number of wire pairs
required by the station interface.
Station wiring between the Coral IPx 500 system MDF and the station equipment
should contain at least two, and preferably three wire pairs to ensure adequate wiring
capacity. At the station location, the station wiring should be terminated with a
modular, six position, telephone jack, containing at least four conductors (pins 2, 3, 4,
and 5).
Figure 5-2
illustrates typical jack configurations with wire designations for four station
types:
2-wire single-line telephones SLT and digital station sets (FlexSet, APDL, CPA,
GKT, DKT, DST) need only connect Tip [T] and Ring [R] or <UpA> and <UpB> as
shown.
FlexSet 280 series or FlexSet APDL units with PEX or PEX+APA, DKT 2000 sets
with PEX or APA; need an extra 2 wires when power is supplied through the line
connector. The polarity of this connection is irrelevant. When using the TPS (single
unit Telephone Power Supply), no additional wires are required.
For peripheral device installation, refer to the
Coral Terminal Equipment Installation
Manual
”.
To prevent a potential shock hazard to station users and damage to the system, make
sure that station circuits extended over cables that exit the building are adequately
protected from lightning and surge currents. See
page 5-9, Protection Devices
for
protective device specifications.
1
Station Equipment
Summary of Contents for Coral IPx 500
Page 22: ......
Page 26: ......
Page 28: ......
Page 42: ......
Page 58: ...2 16 Coral IPx 500 Installation Manual Site Inspection 2 NOTES...
Page 120: ......
Page 126: ...3 6 Coral IPx 500 Installation Manual Power Supply Test 3 NOTES...
Page 152: ...3 32 Coral IPx 500 Installation Manual Installation Wrap up 3 NOTES...
Page 154: ......
Page 170: ......
Page 184: ...5 14 Coral IPx 500 Installation Manual Protection Devices 5 NOTES...
Page 188: ...5 18 Coral IPx 500 Installation Manual Power Fail PF Transfer Circuits 5 NOTES...
Page 204: ...5 34 Coral IPx 500 Installation Manual MDFipx Units Supplied by the Manufacturer 5 NOTES...
Page 256: ......
Page 288: ...6 32 Coral IPx 500 Installation Manual Coral IPx 500M Main Cage Description 6 NOTES...
Page 296: ...6 40 Coral IPx 500 Installation Manual Coral IPx 500X Expansion Cage Description 6 NOTES...
Page 316: ......
Page 332: ...7 16 Coral IPx 500 Installation Manual PS500 DC Power Supply Unit 7 NOTES...
Page 350: ...7 34 Coral IPx 500 Installation Manual PS500 AC Power Supply Unit 7 NOTES...
Page 376: ......
Page 380: ...8 4 Coral IPx 500 Installation Manual Control Cards 8 NOTES...
Page 404: ...8 28 Coral IPx 500 Installation Manual IMC8 Card Flash Erasable Software Memory Unit 8 NOTES...
Page 412: ...8 36 Coral IPx 500 Installation Manual DBX Card Database Expansion Memory Unit 8 NOTES...
Page 426: ...8 50 Coral IPx 500 Installation Manual CLA Card CoraLINK Adapter 8 NOTES...
Page 428: ......
Page 432: ...9 4 Coral IPx 500 Installation Manual Shared Service Circuitry Installation 9 NOTES...
Page 460: ...9 32 Coral IPx 500 Installation Manual Three Way Conference Conference Circuitry 9 NOTES...
Page 490: ...9 62 Coral IPx 500 Installation Manual KB1 KB2 KB3 RS 232E Data Serial Port 9 NOTES...
Page 498: ...9 70 Coral IPx 500 Installation Manual Music Background and Music On Hold M1 M2 9 NOTES...
Page 518: ...9 90 Coral IPx 500 Installation Manual Relay Contacts RLY1 RLY2 RLY3 9 NOTES...
Page 520: ......
Page 526: ...10 6 Coral IPx 500 Installation Manual Peripheral Card Installation 10 NOTES...
Page 543: ......