INSTALLATION AND OPERATING INSTRUCTIONS

DHW CIRCULATION PUMPS FOR POTABLE WATER SYSTEMS

TACOFLOW2 PURE PLUS 15-14/80

Summary of Contents for TACOFLOW2 PURE PLUS 15-14/80

Page 1: ...Group AG Neunbrunnenstrasse 40 CH 8050 Zurich T 41 44 735 55 55 F 41 44 735 55 02 group taconova com V1 12 2021 Art Nr 216221 EA Nr 1374 INSTALLATION AND OPERATING INSTRUCTIONS DHW CIRCULATION PUMPS F...

Page 2: ...9 9 1 Assembling the power plug 30 10 Filling and Venting the System 30 11 Service and Maintenance 31 12 Faults Causes and Remedies 32 13 Disposal 32 Inhalt 1 Konformit tserkl rung 3 2 Sicherheitshinw...

Page 3: ...claration est conforme la aux norme s ou autre s document s normatif s EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 16297 1 2012 EN 60335 2 5...

Page 4: ...s listed under section 2 and the special safety instructions detailed in the other sections A copy of the EC Declaration of Conformity is provided with these instructions This declaration shall be dee...

Page 5: ...st have relevant qualifications Areas of responsibility and monitoring of personnel must be guaranteed by the owner operator If personnel do not have the necessary know how they must be trained or ins...

Page 6: ...ids resulting from a leak Failure of prescribed repair and maintenance work 2 5 Safety conscious working Observe the safety instructions detailed in this manual along with the current national acciden...

Page 7: ...in advance with the product using the operating instructions Conducting work on the pump is only permitted when the system is shut down Ensure that the device is securely disconnected from the power...

Page 8: ...t values detailed in the techni cal data 3 Transport and Storage After receiving the product inspect it immediately for damage caused in transport Should you detect any transport damage assert a claim...

Page 9: ...gungsspannung Emissions Schalldruckpegel Schutzart W rmeklasse Umgebungstemperatur Medientemperatur Systemdruck Max Zugelassene F rdermedien 1 4 m 650 l h Gewindemuffe IG 80mm 1 210kg 2 5 7 0 1 x 230V...

Page 10: ...ts 5 2 Scope of delivery Original installation and operating instructions Pump 2 flat gaskets Insulation Power plug 6 Description of the Pump In an average household around 10 to 20 of the energy cons...

Page 11: ...ture control without time switch function After switching on the mode symbol lights up at the bottom left of the display The pump runs in this operating mode 24 hours a day When the temperature of the...

Page 12: ...set start temperature and runs until the temperature of the tap water reaches the set stop tempe rature To set the time periods proceed as follows Press the left menu button to enter the selection mo...

Page 13: ...the electric pump is switched on and runs until the temperature of the tap water has reached the set stop temperature The time setting can be adjusted become To do this follow these steps With the sm...

Page 14: ...g The stop temperature and the start temperature of the pump can be changed The stop temperature is at least 2 C higher than the start temperature and the temperature setting range is 20 60 C Setting...

Page 15: ...h the OK button Time set flashes and after approx 10 seconds the pump switches to normal operation The current time is now set 7 6 Setting the speed level The pump has three power levels The set level...

Page 16: ...when the tap is opened Assemble the pump with the horizontally positioned pump motor when the power is shut off the arrow on the pump housing shows the direction of flow Ensure when performing the he...

Page 17: ...ions e g IEC VDE etc The current type and voltage must correspond with the information on the type plate Observe the specifications of local energy supplier Observe accident prevention regulations Nev...

Page 18: ...g Connect the power cable to the pump as shown Caution Line voltage Observe the required protective measures national body regulations and local provisions at all times The cable cross section may no...

Page 19: ...vice and Maintenance The pump is nearly free of maintenance If the pump was not wor king for a longer time or the system is heavily contaminated could the rotor be blocked It will shown by flashing of...

Page 20: ...ing 8 Pump housing 12 Faults Causes and Remedies Maintenance work or repair attempts may only be undertaken by qualified persons Switch off the power to the system before performing maintenance cleani...

Page 21: ...mp fails and stops operating Within 10s after the error has been corrected a normal operation resumed E3 E4 E5 electronic error Perform reset If the error persists the pump must be replaced E6 rotor b...

Page 22: ...wer than 5 degrees the water flow is circulated to ensure that the pipeline does not freeze In this case the pump will run for 5 minutes at low speed As soon as 10 C is reached on the circulation line...

Page 23: ...V1 12 2021 Art Nr 216221 EA Nr 1374 Installation and operating instructions taconova com 23 TacoFlow2 Pure PLUS...