Taco Viridian VR1816 Instruction Sheet Download Page 1

Viridian VR1816

Instruction Sheet

102-499

SUPERSEDES: New

EFFECTIVE: August 1, 2014

Plant ID No. 001-4230

Infinitely Variable Speed, ECM High-Efficiency Circulator

DESCRIPTION:

The  Viridian  VR1816  circulator  is  an  infinitely  variable  speed  wet  rotor  circulator
with  an  ECM,  permanent  magnet  motor.  Operating  modes  include  infinitely
adjustable fixed speed or self-adjusting proportional or constant pressure variable
speed. Its high efficiency motor reduces power consumption by up to 85% com-
pared to equivalent AC permanent split capacitor circulators.

APPLICATION:

• Maximum operating pressure: 145 psi

• Maximum water temperature: 230°F (110ºC)

• Electrical specifications:

Voltage: 110-120V, 50/60 Hz, single phase
Maximum operating power: 44W
Maximum amp rating: 0.54

• Equipped with a cast iron casing and should be used for closed

loop systems only.

• Taco circulator pumps are for indoor use only – employer uniquement a

l’interieur.

• Acceptable for use with water or maximum of 40% water/glycol solution.

FEATURES:

• 3 operating modes:

- Fixed speed (     ) - infinitely adjustable min/max settings
- Constant pressure (

), variable speed - 3 constant pressure differential curves (5, 10, or 15 feet of head)

- Proportional pressure (

), variable speed - 3 variable pressure differential curves (High, Med, or Low)

• Multi-color LED display showing operating mode and error code diagnostics.

• Use with a Taco ZVC Zone Valve Control or SR Switching Relay for ON/OFF operation.

• Integral Flow Check (IFC) is included in carton. Simply press into discharge flange if required.

• Nut capture feature on flanges for easier fit up.

• Whisper quiet operation.

INSTALLATION:

WARNING: Do not use in swimming pool or spa areas. Pump has not been investigated for these applications.
AVERTISSEMENT: Ne pas utiliser dans une piscine ou un spa. La pompe n'a pas été étudiée pour ces applications.

CAUTION: The addition of petroleum based fluids or certain chemical additives to systems using TACO equipment
voids the warranty. Consult factory for fluid compatibility.
ATTENTION:  L'ajout  de  liquides  à  base  de  pétrole  ou  de  certains  additifs  chimiques  à  des  systèmes  utilisant  un
équipement TACO annule la garantie. Consultez le fabricant pour connaître la compatibilité de liquides.

CAUTION:  Installations  at  elevations  over  5000  feet  must  have  higher  fill  pressure  of  20  psi  minimum  to  prevent
pump cavitation and flashing. Premature failure may result. Adjust expansion tank pressure to equal fill pressure. A
larger size expansion tank may be required.
ATTENTION: Des installations à des altitudes de plus de 1600 mètres doivent présenter une pression de remplissage
plus élevée de 20 psi au minimum afin d'éviter toute cavitation ou flashing de la pompe. Une défaillance prématurée
peut en résulter. Réglez la pression du réservoir d'expansion de façon qu'elle soit égale à la pression de remplis-
sage. Un réservoir d'expansion d'une taille supérieure peut être nécessaire.

Summary of Contents for Viridian VR1816

Page 1: ... a Taco ZVC Zone Valve Control or SR Switching Relay for ON OFF operation Integral Flow Check IFC is included in carton Simply press into discharge flange if required Nut capture feature on flanges for easier fit up Whisper quiet operation INSTALLATION WARNING Do not use in swimming pool or spa areas Pump has not been investigated for these applications AVERTISSEMENT Ne pas utiliser dans une pisci...

Page 2: ...ONE 1 ZONE 2 V2 V2 V3 V3 P P ZONE 3 ZONE 3 V2 V3 P AIR PURGING SEQUENCE BY ZONE LAST FIRST KEY VI V2 V3 SHUT OFF ISOLATION VALVE P TACO CIRCULATOR WITH IFC FF FAST FILL BOILER FEED VALVE PV4 PURGE VALVE RECOMMENDED PURGING STEPS 1 CLOSE V1 PV4 V2 2 OPEN V3 3 OPEN FF VALVE 4 OPEN V2 PV4 TO PURGE LAST ZONE FIRST ZONE 3 5 CLOSE FF VALVE 6 CLOSE V2 PV4 7 REPEAT STEPS 1 TO 6 FOR EACH ADDITIONAL ZONE PU...

Page 3: ...GING SEQUENCE BY ZONE LAST FIRST P P ZV3 ZV2 ZV1 M ZV1 ZV2 ZV3 M M M M M 3 KEY VI V2 V3 SHUT OFF ISOLATION VALVE P TACO CIRCULATOR WITHOUT IFC INSTALLED FF FAST FILL BOILER FEED VALVE PV4 PURGE VALVE ZV ZONE VALVE RECOMMENDED PURGING STEPS 1 CLOSE V1 PV4 V2 2 OPEN V3 AND ZV3 3 OPEN FF VALVE 4 OPEN V2 PV4 TO PURGE LAST ZONE FIRST ZONE 3 5 CLOSE FF VALVE 6 CLOSE V2 PV4 7 REPEAT STEPS 1 TO 6 FOR EACH...

Page 4: ...g may be rotated to change flow direction Locate the arrow on the casing body to determine flow direction CAUTION To reduce the possibility of noise transmission be sure to add vibration dampeners to piping when mounting circulator to wall or floor joists ATTENTION Pour réduire la possibilité de transmission de bruit veillez à ajouter des amortisseurs de vibration à la tuyauterie lors du montage d...

Page 5: ...eristics of the heating system in question and the actual heat demand CAUTION Never run the circulator dry or permanent damage may result ATTENTION Ne laissez jamais le circulateur tourner à sec des dommages permanents peuvent en résulter The VR1816 has 3 Operating Modes Fixed Speed Infinitely adjustable settings min max Constant Pressure Varies speed to maintain a constant pressure differential P...

Page 6: ...ure differential p c in the system as heating load increases or decreases Selection options are 5 10 or 15 feet of head constant pressure Seee chart above for equivalent 00 model at each setting Low Med High Max Q gpm 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 H ft 0 2 4 6 8 10 12 14 16 18 20 Q l s 0 0 0 2 0 4 0 6 0 8 1 0 1 2 H m 0 1 2 3 4 5 6 Q m 3 h 4 3 2 1 0 Flow Head in Feet PROPORTIONAL VARIABL...

Page 7: ... The circulator performance is too low Increase the suction head Increase speed or P setting Unlocking Procedure A red light in the LED indicates the circulator is locked or sticking Turn the selector to the position MAX disconnect and con nect power supply to start the automatic release process The circulator makes 100 attempts to restart process lasts approx imately 15 minutes Every restart is s...

Page 8: ... of its products without notification TACO OFFERS THIS WARRANTY IN LIEU OF ALL OTHER EXPRESS WARRANTIES ANY WARRANTY IMPLIED BY LAW INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS IS IN EFFECT ONLY FOR THE DURA TION OF THE EXPRESS WARRANTY SET FORTH IN THE FIRST PARAGRAPH ABOVE THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR STATUTORY OR ANY OTHER WARRANTY OBLIGATION ON THE ...

Reviews: