background image

INSTRUCTIONS

1. Unplug the D’Mand System power cord.

2. Connect Black, Green and Red leads from Motion Sensor to corre-

sponding Black, Green and White leads from Black 3-wire cord on
D’Mand System Pump (see wiring diagram). Use wire nuts provided
in kit. Use wire nuts or electrical tape to isolate Red and Black wire
leads in Gray Cord if round starter button is not installed.

D’MAND

®

SYSTEM

Motion Sensor

Installation and Wiring Instructions

102-205

PUMP

POWER

CORD

GRAY

2-WIRE

CORD

RED

BLACK

BLACK 3-WIRE

CORD

BLACK

BLACK

GREEN

WHITE

GREEN

RED

MOTION SENSOR

ROUND

STARTER

BUTTON

Plant ID No. 001-3886         Supersedes: December 1, 2008