ApplICATION:

1.  Maximum operating pressure is 125 psi (862 kPa).

2.  Maximum water temperature not to exceed nameplate rating.

3.  Cast iron circulators are to be used for closed loop systems. Bronze or stainless steel circulators are to be used for

     open loop, fresh water, or potable water systems.

4.  Taco Cartridge circulator pumps are for indoor use only – employer uniquement a l´interieur.

INsTAllATION:

1.  Mounting  position  –  Circulator  must  be  mounted  with  the  motor  in  a  horizontal  position.  It  may  be  mounted

     vertically with the motor up, provided that the system pressure is at least 20 psi (138 kPa).

2.  Rotating body – Body has an arrow on the front that indicates direction of flow. To rotate body, remove the four body 

     bolts, rotate body and replace bolts. Make sure that the junction box is NOT located underneath the circulator. (The 

     junction box must NOT be located in the 6 o’clock position, as viewed from the motor end.)

3.  Electrical connections – Observe all applicable codes when connecting to power supply. The motor is impedance 

     protected, and does not require overload protection. Either colored wire from the capacitor box can be attached to 

     either colored wire from the power supply. There is no “hot” or “common” wire leading from the capacitor box. Typical 

     installation would be to attach the white wire to the white (common) power supply wire and either the yellow or blue

     wire to the black (hot) power supply wire. The pump cannot run backwards.

CAUTION:  1.  The  addition  of  petroleum  based  fluids  or  certain  chemical  additives  to  systems

                       utilizing TACO equipment voids the warranty.

                   2.  Use  supply  wires  suitable  for  90°C  –  ATTeNTION:  employer  des  fils  d´alimentation

                        adequats pour 90°C.

WArNINg: Do  not  use  in  swimming  pool  or  spa  areas;  pump  has  not  been  investigated  for  this

                   application.

WArNINg: In the event the retaining screws have been pulled out of the housing, DO NOT replace

                    them. Use of any other screw may short out the stator windings, creating a risk of elec-

                    trical shock.

4.  Fill system with tap water – The system must be filled before operating the circulator. The bearings are water lubri-

     cated and should not be allowed to operate dry. Filling the system will result in immediate lubrication of the bearings.

     It is always good practice to flush a new system of foreign matter before starting the circulator.

5.  Circulator operation – Operate the circulator for 5 minutes immediately after filling system to purge remaining air from

     the bearing chamber. This is especially important when installing the circulator during the off-season.

CAUTION:  When installing electrical connections, do not apply mechanical loads to the capacitor 

                   box;  otherwise,  retaining  screws  may  be  pulled  out  of  the  housing,  making  circulator 

                   unusable.

CAUTION:  Installations at higher elevations over 5000 feet must have higher fill pressure of 20 psi

                   minimum to prevent pump cavitation and flashing. premature failure may result. Adjust

                   expansion tank pressure to equal fill pressure. A larger size expansion tank may be required.

CAUTION:    DO NOT Use flAT rUbber gAskeTs. ONly Use O-rINg gAskeTs 

prOvIDeD Or leAks mAy resUlT. WArrANTy WIll be vOID.

CAUTION:   Never run the circulator dry or permanent damage will result.