WEB Interface
105
ID: um_tsmux
CP525 cMux User’s Manual Rev. 5.20.12 (3944)
8.4.6.2 Divitech SiGul SI Manager
Figure 8.30
SI Download
The device supports SI downloading from Divitech SIGul SI Manager, using a Divitech XML
protocol for loading. This feature can be used to load SI tables to the device, for later playout
by the PSI/SI playout module. This is configured separately per table on the output page.
Enable
Allow SIGul client to connect.
Port
TCP port to accept connections on. The port number must be agreed upon with the client.
Server state
Status of the embedded download process.
The table at the bottom shows any active connections. The current implementation only allows
one connection at a time.
If the download server is activated and no client connects within the timeout period, the device
alarm "No SI download client" will be raised.
8.4.7 Clock Regulator
This page lets the user configure synchronisation of the internal 27 MHz clock from an external
source.
8.4.7.1 Main
The reference signal is supplied on a separate connector. This page gives access to selecting
how the reference is used.
The
Configuration
field:
27 MHz lock mode
Disabled
The internal clock will not make use of an external reference signal.
Summary of Contents for CP525 cMux
Page 2: ......
Page 10: ......
Page 12: ...12 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 18: ...18 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 24: ...24 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 66: ...66 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 238: ...238 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 248: ...248 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 276: ...276 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...