WARNING:  Risk  of  hyperthermia  and  possible  drowning;  water  temperature 
inexcessof38°C(100.4°F)  may  be  injurious  to  your  health.  Check  and  adjust  water 
temperature before use. 
 
WARNING:  Risk  of  hyperthermia;  people  using  medications  and/or  having  an  adverse 
medical  history  should  consult  a  physician  before  using  a  hydro  massage  bathtub 
equipped with heater. 
 

WARNING:  It is very important that  you carefully follow the basin cleaning procedures 
on page 17 to ensure that the spa is sanitized after each use. T-SPA is not liable for any 
infections  or  disease  that  may  result  from  improper  cleaning  or  failure  to  adhere  to 
sanitation requirements. 
 
This pedicure spa unit should only be operated in a room temperature between 40°F (4°C) and 
100°F (38°C). DO NOT use unit outdoors or in excessively humid or dusty environments. 
 
DO  NOT  use  unit  where  aerosol  (spray)  products  are  being  used  or  oxygen  is  being 
administered. DO NOT operate unit if it has been damaged. 
 
Always  connect  this  unit  to  a  properly  grounded  electrical  outlet.  This unit is designed 
only to operate on a standard 110 Volt 60Hz current. Exceeding this standard may cause 
injury and/or serious bodily harm and/or damage to property. 
 
DO NOT use this unit if noise above normal sound is heard. 
 
To reduce the risk of burns, fires, and electrical shock, never leave this unit unattended if 
plugged  in  and  always  unplug  when  not  in  use  for  an  extended  period,  before 
installation,  cleaning,  or  removal  of  parts.  Keep  the  power  cord  away  from  heated 
surfaces. 
 
DO NOT operate unit if the power cord or plug has been damaged. 
 
If  this  unit  is  operating  abnormally  or  malfunctioning,  immediately  turn  off  the 
power and disconnect the power cord from  the outlet; do not operate unit if it is 
not working properly. 
 
 
 
 
 

      

SAFETY & PRECAUTION 

Summary of Contents for BRIANNA T-200

Page 1: ...10510 10520 Kinghurst St Houston TX 77099 888 508 8772 info tspallc com www tspallc com Page 1 Version T 200 VERSION T 200 MODEL BRIANNA PEDICURE CHAIR OWNER S MANUAL PLEASE SAVE THIS MANUAL FOR FUTU...

Page 2: ...tspallc com www tspallc com Page 2 Version T 200 TABLE OF CONTENTS Safety Precaution 03 Specification 08 Identify Your Foot Spa 09 Foot spa Clearance 10 Installations 11 Operation Use 18 Maintenance U...

Page 3: ...nt WARNING To avoid injury exercise care when entering or exiting the hydro massage bathtub WARNING Risk of accidental injury or drowning do not use drugs or alcohol before or during the use of a hydr...

Page 4: ...40 F 4 C and 100 F 38 C DO NOT use unit outdoors or in excessively humidordusty environments DO NOT use unit where aerosol spray products are being used or oxygen is being administered DO NOT operate...

Page 5: ...ning hazard Check the water temperature before each use water temperature should not exceed 105 F 41 C and water temperature in heater should not exceed 150 F 65 C Disinfect the spa basin and jets aft...

Page 6: ...or death WARNING GROUNDING INSTRUCTIONS AND METHODS This unit must be grounded If it should malfunction or break down grounding provides a path of least resistance for electrical current to reduce th...

Page 7: ...sage chair is equipped with a thermal resetting protection device This is a safety feature to protect it from overheating If the chair should suddenly stop and will not start turn the main power switc...

Page 8: ...ng Pedicure Spa Massage Chair Stool 60 lbs 50 lbs 15 lbs Capacity T 800 3 0 US Gal Switch On Off Air Activated Switch Power Source Dedicated 15A Wall Outlet Require Pipe less whirlpool motor 120V 0 4A...

Page 9: ...t St Houston TX 77099 888 508 8772 info tspallc com www tspallc com Page 9 Version T 200 SEAT OPERATION SPA DIMENSION IDENTIFY YOUR FOOT SPA Armrest can be raised up down Chair Sliding Length 43 Front...

Page 10: ...urst St Houston TX 77099 888 508 8772 info tspallc com www tspallc com Page 10 Version T 200 WALL CLEARANCE TYPICAL FOOT SPA FOOT SPA CLEARANCE 22 between edge of spa and wall 2 3 minimum between mani...

Page 11: ...nfo tspallc com www tspallc com Page 11 Version T 200 Align the seat with pre drilled holes on the base then tightly secure with provided nuts and bolts Attach trays or remote stand to armrest with pr...

Page 12: ...arts 6 Any other use not recommended by the manufacturer may cause electrical shock or injury to person 7 Never use it outdoor 8 Do not attempt to repair or adjust any electrical or mechanical CLEANIN...

Page 13: ...ck cleaning and sanitizing 3 Built in electronic sensor for pump control 4 AC Whirlpool motor long life 5 Very low power consumption 27W 6 Manufactured in the U S A MAGNET JET SPECIFICATIONS Model MAG...

Page 14: ...the unit fitting Please be advised that the Hot and Cold water supply lines are not fitted with optional backflow Preventers unless ordered at initial sale 4 Have a qualified licensed electrician to i...

Page 15: ...n TX 77099 888 508 8772 info tspallc com www tspallc com Page 15 Version T 200 Typical Gravity Sink Direct Drain Installation INSTALLATIONS 2 3 Gravity Sink to sewer line P Trap 1 1 2 or 1 1 4 2 3 Gra...

Page 16: ...8 508 8772 info tspallc com www tspallc com Page 16 Version T 200 Discharge Pump Installation OPTIONAL Hot and Cold Hoses Installation INSTALLATIONS Backflow Valve supplied by plumber Discharge Pump M...

Page 17: ...LC 10510 10520 Kinghurst St Houston TX 77099 888 508 8772 info tspallc com www tspallc com Page 17 Version T 200 Typical Ventilation System Installation OPTIONAL 1 5 inches Output 1 5 inches Input INS...

Page 18: ...HIRLPOOL MAGNETIC JET Press the Jet Button located in the front of your spa This will start your Whirlpool Magnetic Jet To stop the whirlpool function simply press the Jet Button again 3 DRAIN FOOT SP...

Page 19: ...rvised 3 Use this unit only for its intended use as described in this manual DO NOT use attachments that are not recommended by the manufacturer 4 NEVER drop or insert any object into any opening 5 DO...

Page 20: ...components is necessary Remove clean jet caps and spray with disinfectant after each use For extra protection our recommendation is that the system be flushed daily or weekly depending on use To flus...

Page 21: ...FOOT SPA After the foot spa has been installed fill tub with water just above the jets Carefully check for leaks at the drain and motor mount After checking underside for leaks turn on whirlpool syst...

Page 22: ...l on the spa shell 3 Limited One 1 year Parts for the paint on the spa shell 4 Limited One 1 year Parts for the resin sink and fiberglass sink 5 Limited warranty based on shipment for the glass sink 6...

Page 23: ...3 Customers are responsible for shipping defective parts back to T SPA These parts must be packaged correctly to protect against any further damage 4 All parts are to be shipped by Ground services ave...

Page 24: ...T SPA MFG LLC 10510 10520 Kinghurst St Houston TX 77099 888 508 8772 info tspallc com www tspallc com Page 24 Version T 200...

Page 25: ...ed date This Limited Warranty is valid if T SPA received the registration form from the original purchaser FULL NAME EMAIL ADDRESS SALON NAME SALON ADDRESS SECOND ADDRESS Suite Unit CITY STATE ZIP COD...

Reviews: