3
4. Scope of delivery
The scope of the delivery of this product includes:
One booster set with a connection cord, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation", "Anti-dry-
running protection”,
“Operation of the pump with a T.I.P. prefilter” and “How to order spare parts“).
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
5. Installation
5.1.
General installation information
During the entire process of installation, the device must not be connected to the electrical
mains.
The pump should be installed in a dry place with an ambient temperature not to exceed 40 °C
and not to fall below 5 °C. The pump and the entire connection system have to be protected
from frost and other climatic influences.
When installing the device, please make sure that the motor is sufficiently ventilated.
All connection lines have to be perfectly tight since leaking lines may affect the performance of the pump and
cause considerable damage. Therefore, please use Teflon tape to seal the contact surfaces between the
threaded sections of the lines and the connection with the pump. This use of sealing material such as Teflon tape
is the only way to ensure an airtight assembly.
Avoid when tightening screw excessive force that may cause damage.
When laying the connection pipes, you should make sure that the pump is not exposed to any form of weight,
vibration or tension. Moreover, the connection lines must not contain any kinks or an adverse slope.
Please observe the illustrations, too, which are contained as an attachment at the end of the present operating
instructions. The numeric and other details included in brackets below refer to these illustrations.
5.2.
Installation of the suction line
The intake of the suction line has to be equipped with a check valve (or non-return valve) and
an intake filter.
Please use a suction line (2) having the same diameter as the suction port (1) of the pump. If the suction height
(HA) exceeds 4 m, however, it is recommendable to use a 25% larger diameter - including appropriate reducer
elements for the connectors.
The intake of the suction line has to be equipped with a check valve (3) - or non-return valve - and an intake filter
(4). The filter will keep away larger dirt particles contained in the water which might clog or even damage the
piping. The check valve will prevent the pressure to escape after the pump has cut out. Moreover, it simplifies the
venting of the suction line by enabling water to be filled in. The check valve with the intake filter - i.e. the entirety
of the intake section of the suction port - must be immersed by at least 0.3 m below the surface of the liquid to be
pumped (HI). This will prevent air from being taken in. In addition, please ensure a sufficient distance of the
suction line from both the ground and the sides of water courses, rivers, ponds etc in order to prevent stones,
plants etc from being sucked in.
5.3.
Installation of the pressure line
The pressure line (11) conveys the liquids to be discharged from the pump to the point of withdrawal. To avoid
dynamic flow losses, one should use a pressure line having at least the same diameter as the pressure port (5) of
the pump. To protect the pump from damage caused by pressure surges it is advisable to equip the pressure line
with a check valve (6) to be installed directly downstream the pump outlet.
Also, to facilitate maintenance work, it is recommendable to install a shut-off cock (7) after the pump and check
valve. This is a useful feature since it can be closed when the pump has to be dismantled and will thus prevent
the pressure line from draining to empty.
5.4.
Stationary installation
With regard to the electrical connection in the case of stationary installation, please ensure an
adequate visibility and accessibility of the plug.
11
Summary of Contents for HWW G-1000 Plus
Page 52: ...1 T I P 1 1 2 2 3 2 4 3 5 3 6 4 7 4 8 5 9 6 10 T I P 6 11 6 12 8 13 9 14 9 1 RCD FI 30 mA 49...
Page 54: ...3 4 T I P 5 5 1 40 C 5 C Teflon Teflon 5 2 2 1 HA 4 m 25 3 4 0 3 m HI 51...
Page 56: ...5 8 8 9 2 T I P HWW 7 230V AC T I P HWW 8 8 1 T I P 53...
Page 59: ...8 4 1 2 3 4 1 2 1 5 bar 3 2 2 4 2 2 5 1 2 1 2 2 2 6 1 2 1 2 2 2 12 1 2 3 56...
Page 60: ...9 13 www tip pumpen de 14 PDF e mail service tip pumpen de 2012 19 EU 57...
Page 93: ...1 T I P 1 1 2 2 3 2 4 3 5 3 6 4 7 4 8 5 9 6 10 T I P 6 11 6 12 8 13 8 14 8 1 RCD FI 30 mA 90...
Page 95: ...3 4 T I P 5 5 1 40 C 5 C 5 2 2 1 HA 4 25 l 3 4 0 3 HI 5 3 11 5 6 92...
Page 97: ...5 8 8 9 2 T I P HWW 7 230 V T I P HWW 8 8 1 T I P TLS 100 E 94...
Page 100: ...8 12 vis major a 1 2 3 13 www tip pumpen de 14 PDF service tip pumpen de EU EU 2012 19 EU 97...
Page 131: ...1 T I P 1 1 2 2 3 2 4 3 5 3 6 4 7 4 8 5 9 6 10 T I P 6 11 6 12 8 13 8 14 8 1 RCD 30 128...
Page 133: ...3 4 T I P 5 5 1 40 C 5 C 5 2 2 1 HA 4 25 3 4 0 3 HI 130...
Page 135: ...5 8 9 8 2 T I P HWW 7 230 T I P HWW 8 8 1 T I P T I P 30915 TLS 100 E 132...
Page 138: ...8 12 1 2 3 13 www tip pumpen de 14 PDF service tip pumpen de 2012 19 EU 135...
Page 139: ...1 T I P 1 1 2 2 3 2 4 3 5 3 6 4 7 4 8 5 9 5 10 T I P 5 11 6 12 8 13 8 14 8 1 30 136...
Page 141: ...3 4 T I P 5 5 1 5 C 40 C 5 2 2 1 HA 4 25 3 4 0 3 HI 5 3 11 5 6 7 138...
Page 144: ...6 T I P T I P G5 31052 G7 31058 11 12 1 5 T I P 30905 1 1 2 3 4 5 1 2 3 4 5 141...
Page 146: ...8 12 1 2 3 13 www tip pumpen de 14 PDF service tip pumpen de 2012 19 EU 143...