- 145 -
6.9.6 Compile
Press “
↑ ↓
” in main interface of Program, to select program and press “P”,or Press “F1” key
on editing interface of program, the system will check the format and grammar of program.
Prompting when finding mistake automatically.
Note: Before run program, it should compile successfully.
6.9.7 Folder management
User can build a folder in this system, Press “F1” in main interface of Program to import a name
of folder ,add “.” , and press “Enter”to build a folder and it will prompt a “[
夹
]” after the name.
Note: the name of folder must be different to name of other file/folder,otherwise failure.
Move the cursor to the folder and press “Enter” to open folder , user also can build a new file
or folder in this folder.
Press “A” go to the last folder.
Move the cursor to the folder and press “Del” to delete the folder.
6.9.8 Execute Program
Press “
↑ ↓
” in main interface of Program to select a program and press “C” to select the
processing program and switch into main interface of cnc system.
6.9.9 Communication
The system could deliver files with RS232 serial protocol .
There are two communication port for RS232 at front & rear of panel.
Remark
PIN
Function
RXD
PIN2 of Front DB9 Port
Receive Date
TXD
PIN3 of Front DB9 Port
Send Date
0V
PIN5 of Front DB9 Port
Ground
Delivery (Transmit)
Deliver the selected program in this system to another system or to PC for save. Press “
↑ ↓
”
in main interface of Program to select the program and press “T” to deliver, press “Reset” to
interrupt delivery.
Reception
Receive the selected program in another system or PC (Must be text file form). Press “R” to
import a name of received program into the dialog box in main interface of Program , press “Reset”
to interrupt reception.
Note: 1. Using the exclusive communication software to deliver program in User’s PC.
2. The rate of deliver of both PC&CNC must be the same,otherwise failure easily.P37 in Other
parameter is set the rate of CNC system.
3. The length of RS232 can’t over 10 meters.
4. The number of serial port must be the same as the system setting.
5. Editing program of PC must be text file form.
6.9.10 U-disk management
To exchange files of parameter or programs with other system or PC by U-disk. It also can
upgrade or back-up the software or parameter in system.
Note: The name of folder can’t have blank symbols.
Suggestion: Please prepare special USB-disk for manage files for CNC system.
Press “F6”-USB-disk to enter the U-disk in main interface after U-disk is connected to USB
port in the front of panel. Press “F6”-SYSTM again to back interface of system.