1. Introduction   
 
Welcome to choose this product! 
This  is  a  kind  of  31/2  bit  portable  digital  Clamp-Shape  meter,  which  may 
measure AC current and AC & DC voltage, resistance, test for connection and 
disconnection,  positive  voltage  on  diode,  temperature,  frequency,  phase 
sequence  etc..  The  meter  is  the  ideal  tool  of  the  industries  of  electricity, 
electronics and refrigeration due to wonderful structure, easily operated, more 
portable.           
2. Safety 
 
The  meter  is  designed  in  accordance  with  the  safety  requirements  of  the 

standard IEC1010-1. Please   

Carefully read this manual before operate it.     
 
2.1 Note for safety symbols: 

           

  Warning hint, Caution! 

           

  Danger by high-voltage shock! 

  Double insulation protection   

 

2.2 During measuring, any range may not exceed its input value in Max 
2.3 At resistance range, not allowed to impose voltage on input 
2.4 During measuring, to prevent the meter from damage, do not turn its round 
switch to change its range.   
2.5  Over  DC60V  or  AC30V  may  be  shock  danger,  carefully  operating  during 
measuring.   
2.6 During clamping non-insulation wire, must specially be careful to avoid     
2.7  During  measuring  current,  fingers  must  be  placed  on  the  back  of  the 
armguard of the meter. 
2.8 The meter shall avoid straight sunlight, high temperature and humidity. 
2.9 After measuring end, the turning switch shall be at OFF. 
2.10 Idling for long term, its batteries shall be taken out to prevent the batteries 
from leaking liquid to damage parts.   
 
3. Features 
 
3.1 Displaying mode: LCD displayer 
3.2 Maximum display: 1999 
3.3 Maximum open: 30mm 
3.4 Automatic negative indication: Displaying “-“ 
3.5 Low battery indication: Displaying “

” 

3.6 Operating environment: 0

C~40

C

70%RH(Max.) 

3.7 Storage environment: -10

C~60

C

85%RH(Max.) 

3.8  Power  supply:  9V  battery  (IEC6F22,  NEDA1604,  JIS006P  or  equivalent 
types),   
3.11 Size 221

Length

75

Width

31

Height

mm 

3.12 Weight: about 240gram

with batteries

 

 
4. Usage of Clamp-Shape Meter with Manual Range 
 
4.1 Instruction on operating panel (see figure) 

1

) 

Clamp mouth 

2

) 

Trigger   

3

) 

Range  switch:  choosing  current,  voltage,  resistance,  frequency, 
forward voltage on diode, test for connection and disconnection and 
range.   

4

) 

DH reading holding button: pressing the button may lock the current 
reading,  and  displaying  “DH”  symbol,  repressing  the  button  to 
cancel the holding function, “DH” symbol disappears. 

Phase sequence: At range AC600V, “DH” button is the switch to measure 

phase  sequence,  pressing  the  button  to  display  “    “symbol  for  measuring 
phase  sequence,  repressing  the  button  to  cancel  the  function,  “    “symbol 
disappears.     

5

) 

LCD 

6

” COM” for common input ( input ground) 

7

“V/

”voltage-resistance-frequency-temperature input jack 

8

  Armguard 

 

 

 
4.2 Measurement of AC voltage 
Turn  the  range  switch  into  the  range  “A600V”,  Plug  the  black  pen  into  the 
jack“COM”

the red pen into the jack“V/

in parallel connect the pens with 

the measured circuit

read the displaying number. 

4.3 Measurement of DC voltage 
Turn  the  range  switch  into  the  range  “D600V”,  Plug  the  black  pen  into  the 
jack“COM”

the red pen into the jack“V/

in parallel connect the pens with 

the  measured  circuit

read  the  displaying  number.  When  the  reading  is less 

than 20V, turn the range switch at range ”DC20V” to measure again.     
4.4 Measurement of AC current 
Turn  the  range  switch  into  the  range  “AC600A”,  clamp  the  wire  of  the 
measured current, shall put the wire into the canter of the completely closing 
clamp mouth as soon as possible, directly get the reading. When the reading is 
less, turn the range switch at lower range to measure again. 

  Cautions

If  two  or  more  than  two  different  wires  are  clamped,  the 

measuring can’t be done. 
4.5 Measurement of resistor and connection & disconnection 

1

) 

Turn the range switch into the range 2k

 

2

    plug the black pen into the jack“COM”

the red pen into the jack“V/

” 

3

    In parallel connect the pens into the two terminators of the measured 

circuit or component

get the reading. 

4

    when the two pens open or input overload

the displayer shows “1” 

4.7 Measurement of forward voltage of diode 

1

    Turn the range switch into the range

when the input opens, the 

meter shows over range

show“1”

)。

 

2

    Plug the black pen into the jack“COM”

the red pen into the jack“V/

”,

the red pen’s polarity is“+”

 

3

  In parallel connect the pens into the two terminators of the measured 

diode

get the reading for approximation of the forward voltage. 

4

  when the diode is connected in reverse or the input open

the displayer 

shall show “1”. 
4.8 Test of connection and disconnection 

1

Turn  the  range  switch  into the  range 

when  the  input  opens, the 

meter shall show over range

show “1”

)。

 

2

Plug the black pen into the jack“COM”

the red into the jack“V/

 

3

In parallel connect the two pens into the two terminators of the measured 

circuit

if the resistance between the tested two points is less than approximate 

50

the buzzer shall make a sound. 

   

  Cautions: resistor, diode and connection and disconnection sharing the 

same  range,  when  measuring,  the measured component  or circuit cannot  be 
electrified, otherwise, shall misjudge. 
4.8 Test of connection and disconnection 

1

Turn  the  range  switch  into the  range 

when  the  input  opens, the 

meter shall show over range

show “1”

)。

 

2

Plug the black pen into the jack“COM”

the red into the jack“V/

 

3

In parallel connect the two pens into the two terminators of the measured 

circuit

if the resistance between the tested two points is less than approximate 

50

the buzzer shall make a sound. 

   

  Cautions: resistor, diode and connection and disconnection sharing the 

same  range,  when  measuring,  the measured component  or circuit cannot  be 
electrified, otherwise, shall misjudge. 
4.9 Measurement of temperature 
Turn  the  range  switch  into  the  range 

,  put  the  black  plug  of  K  type 

thermoelectric couple attached with the meter into the jack“COM”, the red into 
the jack“V/

”, here the meter shall show environmental temperature, place the 

detector head on the measured object, get the reading when the detector head 
and the measured object are the same temperature. 

 
 