background image

RF/Serial(RS232) Converter 

BT-232

 

User Manual 

Version 1.1 

(Software version 2.1) 

 
1. Introduction 

BT-232 converts RS-232 serial signals to Bluetooth RF signals. 

 Product box contains 

- RS232 to RF Converter 2EA   

- User Manual 

- A/C power supply(110/220V AC to DC)  - USB cable 

2. Specifications 

Model Name 

BT-232 (Software version 2.1) 

Type 

RS232 to RF Conveter 

Distance 

100 M 

Voltage 

5V ~ 12V/DC 

Wireless interface 

Bluetooth Specification Version 1.1 

Frequency bandwidth  2402 ~ 2480 MHz 
Radio mode 

Frequency hopping 

Channels 

Modulation 

GFSK 

Current 

Max 200 mA (5V DC) 

Temperature 

-20 ~ 70 

°

Antenna 

Internal Chip Antenna 

Antenna gain 

Max 1.5 dBi 

Antenna directivity 

Non-directional 

Antenna  polarization 
characteristics 

None 

Serial 
communication 

1200 BPS 

 115200 BPS Full Duplex 

8 Data bits/Odd, Even, No Parity/1,2 Stop bits 

Flow Control 

RTS/CTS ON/Off possible, 
DTR/DSR/DCD Loop back connected 

3. Architecture 

1) External View 

 

2) Mode Switch 

                      Setup                        Active : Active Mode 

                      Setup                        Active : Setup Mode 

3) LED 

- LINK : Turns green when remotely linked with the other party 

-  TxD  :  Turns  on  when  data  is  transmitting  (turns  on  faintly  only  if 

linked) 

- RxD : Turns on when data is receiving 

4) Connector   

 

DB-9 Connector Pin-out 

4. Installation Procedures 

1) Connection 

There  is  no  need  to  install  additional  programs  in  your  computer  or 

communication devices to use the BT-232. 

Connect  the  BT-232  to  a  serial  port  at  your  computer  or 

communication  device  and  supply  it  with  power.  Then  you  can  easily 

access it as if you were using the existing serial port. 

BT-232  can  be  powered  by  the  following  methods:  DC  power  supply, 

PC USB port through USB cable or DB9 pin connector (available only if 

special serial ports are used). 

A  Bluetooth  connection  between  two  devices  using  the  BT-232  is 

automatically  established  when  both  BT-232  are  powered  on.  After 

that, you are free to use the serial port. 

2) Environment Setting 

Since  BT-232s  are  connected  onto  the  serial  port  of  your  PC  or 

communication  device,  you  should  specify  the  serial  port  environment 

information (Baud rate, data bits, parity bit, stop bit, flow control, etc.) 

and the RF connection (device name, operating mode, target address, 

etc.) for mutual communication. 

RF  connection  setting  is  required  only  if  you  communicate  with  other 

manufacturer

s Bluetooth devices instead of the BT-232 or change the 

initial setting. 

For  environment  setting,  please  use 

Hyper  terminal

  included  in  your 

Windows

 operating system. 

5. Operating Environment Setting 

1) Procedures 

BT-232  can  set  baud  rate,  parity,  stop  bit,  device  name,  target 

adapter and operating mode using Hyper Terminal. 

①. Connect one BT-232 to the PC serial port and power it on. 

②. Run Windows

 Hyper Terminal program. 

③. Set baud rate, data bits, parity and stop bit to   

9600-8-NONE-1 at Hyper Terminal. 

④. Select setup mode at the BT-232 mode switch. 

 

⑤. If you press <Enter>key after 5 seconds, software version 

information will be displayed. 

 

⑥. Set up serial port. 

⑦. Setup RF connection. 

⑧. After completing the setting, be sure to execute 

X

 command and 

save, and then the Mode Switch to 

Active

 

 Reference:   

If  you  enter 

?

,  the  list  for  all  commands  is  displayed,  and  if 

?<command>

,  how  to  use  the  requested  command  is  displayed.  All 

commands  should  be  typed  with  capital  letter.  All  commands  and 

setting values are case-sensitive.   

 

 

2) Serial settings 

 Example of Baud Rate setting (9600 bps -> 19200 bps) 

①.

 

First, enter 

?B

 to display the way to use the requested command. 

To set the baud rate at 19200bps, the input value shall be 

4.

 (Refer to 

the above figure) 

②. Type 

B

 

③. Type 

4

 

④.  The  set  value  is  shown  on  the  screen  again.  (All  the  same  in  the 

next procedures) 

 

 

Example of Flow control setting (None -> Hardware) 

①. First, enter 

?F

 to display the way to use the requested command. 

To set the flow control at Hardware, the input value shall be 

1

②  Type 

F

 

③. Type 

1

 Example of Stop bit setting (1 bit -> 2 bits) 

①. First, enter 

?S

 to display the way to use the requested command. 

To set the stop bit at 2bit, the input value shall be 

1

②  Type 

S

 

③. Type 

1

 Example of Parity bit setting (None -> Even) 

①. First, enter 

?P

 to display the way to use the requested command. 

To set the parity bit at Even, the input value shall be 

2

②  Type 

P

 

③. Type 

2

3) RF Connection setting 

This is necessary only if you communicate with other manufacturer

Bluetooth devices instead of the BT-232 or change the initial settings. 

 Example of Target Address setting 

    (00:02:78:01:EF:BB -> 00:02:78:01:EF:BC) 

①. Type 

A

 

②. Type the target address to be changed. You have to enter the 12-

digit hexadecimal address. After typing 

00027801EFBC

, press 

Enter

 

key. 

 Example of connection mode setting    (1:1 -> Wait) 

Software version 

Authentication

Adapter address

Factory default setting

Target adapter address

Device name

COM port setting