owner’s manual 

7

  When heating 

  Cooling operation 

Adjust the louver horizontally . 

  When cooling 

Adjust the louver horizontally. 

Adjust the louver down(vertically). 

  When heating 

Adjust the louver down(vertically). 

 ■ 

 Adjust the air direction left and right 

 ■ 

 Adjust left and right  

 ■ 

 Adjust the air flow up and down 

Adjust the blade inside the air outlet louver to the desired 
direction.

When the air flow sideways and the air flow parts must be used 
(sold separately), please refer to the following figures to adjust the 
air flow direction.

The louver is horizontal 

NOTE 

1  Please adjust the horizontal louver down when the air flow is  
    down. 

Horizontal louver 

Less than 40° 

 

2   The slant angle of horizontal louver must be 

Less than 40°

     

     otherwise condensation drops may occur.

 

vertical louver 

vertical louver

When adjusting air flow left /right, refer to the following figures to 
turn the vertical louver to certain angles. Do not adjust the blade
angle too much, otherwise condensation drops may form on blade.

NOTE 

The following is how to adjust  the air flow direction when the air 
outlet parts (sold separately) is used with the indoor unit.

To effectively cool the bottom of the room please set the louver 
sideways.

■ 

 Duct-ceiling type 

  When cooling 

  When heating 

To effectively heat the bottom of the room please set the louver  
downwards. 

Fig.4-4 

Fig.4-5  

Fig.4-6 

Fig.4-7 

Fig.4-8   

Fig.4-10 

Fig.4-9 

(Fig.4-9) 

   (Fig.4-10) 

Summary of Contents for VRF series

Page 1: ...SYSVRF Indoor unit VRF Indoor units OWNER MANUAL GB...

Page 2: ...egarding the connection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the ground water and get into the food chain damaging your h...

Page 3: ...llow children to play on the outdoor unit or avoid placing any object on it Falling may result in injury Do not operate the air conditioner when using a room fumigation type insecticide Failure to obs...

Page 4: ...dust in the intake air Grounding Screw In the control box Air Intake Air Out Air Out Louver Adjust the air Aout direction Fig 2 4 Fig 2 7 Fig 2 8 Fig 2 9 Air return grille Induced air decoration Dust...

Page 5: ...let pipe Electric control box Fig 2 10 Fig 2 11 Fig 2 12 Fig 2 14 4 Low static pressure type Air Outlet Connect the duct Grounding Screw In the control box Control Box Air Intake Intake room air Air F...

Page 6: ...and effective operation The Max operation temperature for the air conditioner Cooling Heating 3 AIR CONDITIONER OPERATIONS AND PERFORMANCE Cooling operation Heating operating cooling only type withou...

Page 7: ...the difference of the room temperature The louver direction Choose horizontal outlet mode when cooling operation When the cooling operation the air flow down will cause condensing dew on the air outle...

Page 8: ...down when the air flow is down Horizontal louver Less than 40 2 The slant angle of horizontal louver must be Less than 40 otherwise condensation drops may occur vertical louver vertical louver When ad...

Page 9: ...he horizontal louver with hands or malfunction may occur Adjust it with the swing button on the wire controller 1 2 3 Ceiling floor type Auto swing Press SWING button the louver will swing up and down...

Page 10: ...attern depending on the operating mode situation During Dry mode so that cold air does not come into direct contact with people air is blown upper air outlet Regardless of the operating mode or situat...

Page 11: ...se If the air conditioner is positioned in a dusty place the cleaning frequency of the air filter must be increased If the accumulated dust is too heavy to be cleaned please replace the filter with a...

Page 12: ...in version I proceed as followed Fig 5 9 Fig 5 10 Take off the inlet grille from the panel Air Outlet Selection Switch special function filter For Console Type Push the grille switches to the arrow d...

Page 13: ...e Fig 5 15 Fig 5 16 12 owner s manual Inlet grille According to the figure shown in the position and direction of arrow press the filter and take it down In the same way take down the filter on the ot...

Page 14: ...top or flow change A continuous low hissing sound is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A squeaking...

Page 15: ...Doors and windows are open Direct sunlight Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the comeback of power Switch on the power Replace the...

Page 16: ...signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end wh...

Page 17: ...alfunctions disappear it restores automatically When the indoor unit is replaced with a correct one or is turned off the alarm will disappear Table 7 4 NO Type Contents Display content Remarks Room te...

Page 18: ...SYSVRF indoor units_OM EN April 2014 202000191029 WP MDV03U 011PW...

Reviews: