background image

NOI

R

VER

T/JA

.

RO

SS

O

R

D

BLE

U

NE

G

R

O

BL

U

NER

O

BLU

E

SCH

W

ART

Z

BLA

U

V

T

RO

U

G

E

VI

O

LE

T

VI

O

LA

GNY

E

RE

D

PU

R

PL

E

VIO

LET

T

BU

   

BL

A

CK

GREEN

/YELL

.

RO

T

BK 

 

ROJ

O

B

N

MAR

R

ON

E

GIAL

LO/V

.

AZU

L

BR

O

W

N

GRU

N

/G

.

BRU

N

VERD

E/AM

.

MA

R

RO

N

BR

A

U

N

VIO

LET

A

10

/20

/3

0

40

/50

/6

0

TA

IL

LE

70

80

GM

V

GM

V1

GM

V2

GM

V1

GM

V2

PCB

 S

YSL

OG

IC

 C

ON

TR

OL

 B

OAR

D

VF

 C

OO

LI

NG

 V

ALV

E

KR

 RE

LE

 DE

 CALE

FACC

IO

N

GM

V1

/2

 G

RO

UPE

 M

O

TEUR

 VEN

TI

LA

TEU

R

FC

M

 S

ECUR

IT

CH

AU

FF

AG

M

A

NUELL

E

O

PT

IO

N

S

FCA

 S

ECUR

IT

CHAU

FF

AG

AU

TO

GM

V1

/2

 F

AN

 M

OT

OR

W

PT

 S

ONDE

 DE

 T

EM

PERA

TURE

 D

'EA

U

50

/60

 H

z

F/

PR

OT

EC

TI

ON

 G

EN

ERALE

 

M

PO

M

PE

 DE

 RE

LEVA

GE

SB2

 N

IVEAU

 D

EF

AU

CO

ND

ENSA

T

VCH

 S

ERV

OMO

TE

UR

-EAU

 C

HAUD

E

SA

 S

ON

DE

 REPR

IS

D'

AI

R

CA

BLAG

E CL

IEN

T

F/

GE

NERAL

 PR

OT

EC

TI

ON

W

PT

 W

AT

ER

 S

ENS

OR

3

R1

 E

LE

M

EN

CHA

UFF

AN

T

PCB

 R

EG

ULA

TEUR

 S

YSL

OG

IC

VF

 S

ERV

OMO

TE

UR

-EAU

 F

RO

ID

E

2

3

0

V

CODE :J58156

1

SA

 A

IR

 T

EM

PE

RA

TURE

 S

ENS

OR

VCH

 HEA

TI

NG

 VALV

E

R1

 H

EA

TI

NG

 RE

SI

ST

OR

O

PT

IO

N

S

FC

M

 M

ANUEL

 T

HE

RMO

ST

AT

 S

AF

ET

Y

KR

 RE

LA

IS

 DE

 CH

A

UFF

AG

E

FCA

 A

UT

THE

RMO

ST

AT

 S

AF

ET

Y

GM

V1

/2

 G

RO

UPE

 MO

TO

 VEN

TI

LA

TO

R

PCB

 R

EG

ULA

TO

RE

 S

YSL

OG

IC

VF

 V

ALV

OLA

 F

RI

O

W

PT

 S

ONDA

 D

I T

EM

PERA

TURA

 AC

QU

A

F/

PR

OT

EZ

IO

NE

 G

ENERAL

E

SA

 S

O

NDA

 D

I T

EM

PER

.DEL

L'

AR

IA

VCH

 VALV

OLA

 CAL

O

R1

 EL

ETT

RO

RI

SCA

LDA

TO

RE

O

PZ

IO

N

I

FC

M

 S

EG

URE

ZZ

M

ANUAL

E

FCA

 S

EG

URE

ZZ

AU

TO

M

AT

IC

O

GM

V1

/2

 MO

TO

VEN

TI

LAC

IO

N

sh

un

t à

 o

te

r s

i p

se

nc

CF

PCB

 R

EG

ULAC

IO

SY

SL

OG

IC

VF

 VALV

ULA

 F

RI

O

W

PT

 S

ONDA

 T

EM

PERA

TUR

A

 A

GU

A

F/

PR

OT

ECC

IO

GENERA

L

SA

 S

ONDA

 RE

TO

RN

O

VCH

 VALVULA

 CAL

OR

R1

 R

ES

IS

T.

CALE

FACC

IO

N

O

PT

CI

O

N

A

L

FC

M

 S

EG

UR

IDAD

 M

ANUE

L

FCA

  S

EG

UR

IDAD

 A

UT

OM

AT

GM

V1

/2

 VEN

TI

LA

TO

RMO

TO

RE

INHE

IR

6

PCB

 B

ED

IENPL

A

TI

NE

 SY

SL

OG

IC

VF

 K

A

LT

W

ASSE

M

AG

NE

TV

EN

TI

L

W

PT

 W

ASSER

 T

EM

PERA

TUR

ES

OND

E

F/

SI

CHERUN

G

SA

 R

UCKH

OLLU

FS

OND

E

VCH

 W

AR

MW

ASS

ER

 M

AG

NE

TV

EN

TI

L

R1

 E

LEK

TR

OHE

IZ

UN

GW

IDE

RS

TAN

D

ZU

B

EH

O

R

FC

M

 H

ANDUBER

HI

TZ

UN

GS

SCHU

TZ

FCA

 U

BERH

ITZ

UN

GS

SCHU

TZ

PC

B

Ou

t 2

R

2

Co

m

N

Ou

t 1

L

Co

m

L

O

PTI

O

CHA

U

FF

A

GE

 EL

ECT

R

IQ

U

N

R2

 E

LE

M

EN

CHA

UFF

AN

T

R2

 EL

ETT

RO

RI

SCA

LDA

TO

RE

R2

 E

LEK

TR

OHE

IZ

UN

GW

IDE

RS

TAN

D

R2

 H

EA

TI

NG

 RE

SI

ST

OR

R2

 R

ES

IS

T.

CALE

FACC

IO

N

KR

 H

EA

TER

 R

ELA

Y

KR

 RE

LA

IS

 ELEK

TR

OH

EI

ZUN

G

KR

 RE

LE

 D

I R

ISCAL

DA

M

EN

TO

SB

2

FL

 A

N

TI-I

NT

ER

FERENCE

 F

IL

TE

R

FL

 F

IL

TR

AN

TI

DI

ST

URB

O

FL

 F

IL

TRE

 AN

TI

PA

RAS

IT

E

BK

GY

W

A

TER

 TE

R

MI

N

AL 

EC

 

M

od

m

anag

em

en

t

1

Va

lv

es

GN

WH

BN

Sh

un

t i

ot

er

 if

 p

re

se

nc

CF

2

S

E 4

7

30

Hy

dr

on

ic

Di

p-

sw

itc

h

2

P

IP

ES

SA

1

Co

nfi

g

3

2

P

IP

ES

O

N

5

O

N

6

4

1

1

2

P

IP

ES

4

P

IP

ES

2

P

IP

ES

3

2

7

7

3

2

1

2

3

2

1

2

ON

3

1 ON

ON

3

1

ON

2

2

P

IP

ES

2

P

IP

ES

SB1

 N

IVEAU

 M

AR

CHE

 M

P

L

N

23

0V 

 50

H

z+

N

L

BN

VF

VC

H

BN

BU

BU

GN

YE

GY

BK

CF

BU

BN

PC

B

WPT

2x

BK

2x

RD

OG

BU

BU

BN

BU

OG

RD

RD/WH

R1

WH/BN

WH/BN

BK

BK

VT

GY

KR

FC

M

FC

A

BU

OU

M

O

TO

R

G

M

V

1

BN 
BU

VT

BK

N

L

GN/YE

G

N

D

BN

VC

T

VT/OG/B

N

G

M

V

2

BN

BU

BU

OG/B

N

GN/YE

BK/BU

BU

BU

BN

BN

BU

BK

VT

OG/B

N

3

ON

1

2

3

1

2

1

0

1

1

C

oo

lin

on

ly

R

ev

er

si

bl

e/

ch

an

ge

 o

ve

r

H

ea

tin

+

C

oo

lin

g

H

ea

tin

on

ly

R

ev

er

si

bl

e/

ch

an

ge

 o

ve

r

C

oo

lin

+

El

ec

tri

he

at

er

R

ev

er

 /C

O

 +

El

ec

tri

he

at

er

M

P

SB

1

GN

YE

L

N

BN

BU

N

O

N

 F

O

U

R

N

I

CF

 C

O

NT

AC

DE

 F

ENE

TR

E

N

O

 F

IT

TE

D

CF

 W

IND

OW

 C

O

NT

AC

T

M

CO

NDENSA

TE

 PU

M

P

SB1

 W

AT

ER

 LEV

EL

 SENS

OR

 M

ON

SB2

 W

AT

ER

 LEV

EL

 SENS

OR

 ALAR

M

N

O

 F

O

R

N

IT

A

CF

 IN

TERRU

TO

RE

 F

INES

TR

A

M

M

O

TO

RE

 P

OM

PA

 C

OND

ENSA

TO

SB1

 S

ENS

ORE

 D

I L

IVELL

A

CQ

UA

  M

AC

IA

 M

P

SB2

 S

ENS

ORE

 D

I L

IVELL

AL

LAR

M

E

N

O

 S

U

M

IN

IS

TR

A

D

O

CF

 C

ON

TAC

TO

 DE

 V

EN

TAN

A

M

M

O

TO

BOM

BA

 C

ONDE

N

SAD

OS

SB1

 C

A

PT

AD

OR

 DE

 N

IVEL

 DE

 A

GUA

 M

P

SB2

 C

AP

TAD

OR

 D

NI

VEL

 DE

 A

GUA

 A

LAR

M

A

B

A

U

SE

IT

S

CF

 F

ENS

TE

R

M

MO

TO

RPU

M

KO

N

DENSA

T

SB1

 W

A

SSERS

TAND

M

ESS

FUHLER

 M

EI

N

SB2

 W

ASSERS

TA

DM

ESS

FUHL

ER

 ALAR

M

 S

IG

NA

L

CU

STO

M

ER 

CABL

IN

G

CA

BLE

A

DO 

CLIE

N

TE

CA

BLAG

G

IO 

CLIE

N

TE

V

E

R

K

A

B

E

L

U

N

G

 

K

U

N

D

E

4

BU

OG

c

nc

SY

SLO

G

IC

A

1

A

2

FL

 IN

TER

FEREN

ZF

IL

TE

R

FL

 F

IL

TRA

 AN

TI

PA

RAS

IT

O

GN

YE

N

N

L

L

FL

Sh

un

t i

ot

er

, w

en

A

nw

es

en

he

it 

CF

de

ri

va

to

re

 a

 to

gl

ie

re

 s

pr

es

en

za

 C

F

Sh

un

t a

 o

te

r s

i p

re

se

nc

ia

 C

F

8

BK

GY

\

(

1)

(

1)

\

(

1)

(

1)

Sup

ply

L

N

23

0V

AC

Co

m

Com

Com

Out

 1 

(He

ating

/Coo

ling

 va

lve

)

Out

 2 

(No

t u

sed

/He

atin

g v

alv

e/

Ele

ctri

c hea

ter

)

Dig

ita

l in

put

GND

 

SIG

+12

V

LCD

 te

rm

ina

con

nec

tion

GN

D-0

V

SIG

-10

V

AC

 F

AN

EC

 F

A

N

M

ax

M

ed

M

in

TT

L

DM

I c

onn

ec

tion

An

al

og

ic

 te

rm

in

al

 c

on

ne

ct

ion

Ai

r p

ro

be

W

at

er

 p

robe

RS

-4

85

(m

odb

us

)

ON

1

2

3

DI

SW

IT

CH

 to 

co

nf

ig

ur

pr

od

uc

t

M

od

e

+12

V

SI

G

GN

D

>

>

F/

Q

1

4

1

1

2

4

2

1

KR

XII SysCoil Comfort

APPENDIX / ANNEXE / ANLAGE / ALLEGATO / ANEXO

SE 4730 - SYSCOIL COMFORT EC MOTOR SYSLOGIC

Summary of Contents for SysCoil Comfort SCC10

Page 1: ...Fan coil units Installation and maintenance manual 84 1 548m3 h 0 53 9 55kW 0 64 13 60kW 10 80 SysCoil Comfort...

Page 2: ......

Page 3: ...INSTALLATION INSTRUCTION NOTICE D INSTALLATION INSTALLATIONSHANDBUCH ISTRUZIONI INSTALLAZIONE INSTRUCCIONES DE INSTALACI N English Fran ais Espa ol Deutsch Italiano...

Page 4: ...0 8 5 INSTALLATION OF THERMOSTAT OR TEMPERATURE SENSOR CHANGE OVER 10 8 5 1 TRM FA 10 8 5 2 TAE20 OR SYSLOGIC 10 8 6 WATER QUALITY 11 9 ELECTRICAL CONNECTIONS 12 9 1 WIRING DIAGRAM AND LEGEND 12 9 2 P...

Page 5: ...ssible assemble the compulsory or optional accessories before placing the appliance on its final location see instructions provided with each accessory In order to become fully familiar with the appli...

Page 6: ...e and send immediately a registered letter to the shipper within 48 hours clearly stating the damage caused Forward a copy of this letter to the manufacturer or his representative Never store or trans...

Page 7: ...g Gg Fuse rating ASE VDE Cable section mini W A A mm SCC10 500 4 10 3G1 5 SCC20 500 4 10 3G1 5 SCC30 500 4 10 3G1 5 1 000 4 10 3G1 5 SCC40 1 250 8 10 3G2 5 2 500 16 16 3G2 5 SCC50 1 250 8 10 3G2 5 2 5...

Page 8: ...NIT LOCATION Fan coil units are designed to be installed in a controlled environment Each unit should be located on the installation plans Inspect the carton for specific tagging numbers and reference...

Page 9: ...mentioned Install the fixing screws contractor supply Place the chassis unit on the fixing points and screw it directly to the ceiling or to the veritable support The fan coil unit should be pitched t...

Page 10: ...ld the casing attached to the two chassis flanks 8 HYDRAULIC CONNECTIONS 8 1 OPERATING FACE The operating face of Left Right versions is defined in relation to the position of the hydraulic connection...

Page 11: ...CC80 with chilled water coil and heated water coil 1 row on an independent circuit The coil headers are equipped with air vent To vent the air from the coil use the air vent located on the upper part...

Page 12: ...is at a 90 degree angle between the wall and floor see fluorescent sticker on unit chassis Note If the floor and the wall are not at right angle it may be necessary to shim the fan coil unit to insure...

Page 13: ...treated or improperly treated water demineralized water salty water or sea water are used Apply the following guidelines No NH4 ammonium ions in the water highly detrimental to copper 10mg l Cl chlori...

Page 14: ...ysCoil Comfort AC motor TBMV 2P 2P REV 230V 50Hz 60Hz 10 SE 4557 SysCoil Comfort EC motor TBMV 2P 2P REV 230V 50Hz 60Hz 10 9 1 WIRING DIAGRAM AND LEGEND 9 2 POWER SUPPLY The electrical installation mu...

Page 15: ...w voltage wiring must be done in accordance with electrical code whichever is applicable Earthing of unit is imperative Note if electrical wiring or conduit comes through the floor they must be tight...

Page 16: ...HERMOSTAT TRM FA 9 5 1 2 1 USE 9 5 1 2 2 USWITCHES 9 5 1 2 3 DIMENSIONS The room thermostat of the air conditioner regulates the room temperature It is designed for closed dry rooms such as flats offi...

Page 17: ...eed 9 5 1 2 7 FINAL OPERATIONS ADJUSTMENT OF THE TEMPERATURE RANGE The room thermostat is set in the factory for a minimum temperature of 5 C and a max temperature of 30 C Two rings are provided insid...

Page 18: ...cessible by removing the button 5 4 Maximum temperature setting limiter adjustable by increments of 1 K Mechanical stop accessible by removing the button 5 5 Ambient temperature setting adjustment but...

Page 19: ...sates actually drain properly installation with or without drainage pump by pouring water into the condensates tray pump electricity supply switched on 10 1 3 VISUAL CHECK 1 Unit mounted as specified...

Page 20: ...he order confirmation and the unit serial number indicated on the name plate must be provided whenever service works or spare parts are ordered For any spare part order indicate the date of unit insta...

Page 21: ...onditions Some applications such as hotels where there is a lot of lints from carpeting will require more frequent filter changes If light cannot be seen through the filter when held up to sunlight or...

Page 22: ...the fluid circulates freely without any sign of leaks or air bubbles 14 1 3 CONDENSATE RECOVERY TRAY 1 Check that the drainage orifices conduits and siphon are not blocked 2 Eliminate all accumulated...

Page 23: ...APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO APPENDIX ANNEXE ANLAGE ALLEGATO ANEXO...

Page 24: ...AC CMV VIII SE 4548 SYSCOIL COMFORT MOTOR AC TBMV 4P 2PEH IX SE 4729 SYSCOIL COMFORT MOTOR AC SYSLOGIC X SE 4550 SYSCOIL COMFORT MOTOR EC KLEMMENLEISTE XI SE 4551 SYSCOIL COMFORT MOTOR EC CMV XII SE...

Page 25: ...C HC Dimensions are in millimeters A B C D E F G H Weight SCC10 240 428 360 189 415 5 61 766 477 20 SCC20 240 428 360 189 415 5 61 766 477 20 SCC30 240 613 360 374 415 5 61 951 477 23 SCC40 240 798 36...

Page 26: ...A B C D E F G H I Weight SCC10 66 5 428 185 5 189 415 5 61 569 5 430 407 14 SCC20 66 5 428 185 5 189 415 5 61 569 5 430 407 14 SCC30 64 613 184 374 415 5 61 753 430 592 16 SCC40 64 798 184 559 415 5 6...

Page 27: ...Left 4 pipes Right 2 pipes Left 2 pipes A B C D E F G H SCC10 295 100 337 71 277 139 400 53 SCC20 295 100 337 71 280 164 382 92 SCC30 295 100 337 71 280 164 382 92 SCC40 295 100 337 71 280 164 382 92...

Page 28: ...t gelieferten Stromlaufplan hinzuziehen ATTENZIONE Questi schemi sono corretti al momento della pubblicazione Le varianti apportate nel corso della fabbricazione possono comportare modifiche Far sempr...

Page 29: ...HERMOSTAT OPZIONE SCH MONTANA PER TAE20 TERMOSTATO OPCION SCH SUBIDA PARA TAE20 TERMOSTATO AUFGERICHTETE OPTION SCH FUR THERMOSTAT TAE20 M KR RELAIS DE CHAUFFAGE SW SCH SONDE DE TEMPERATURE D EAU KR H...

Page 30: ...ER SCHUTZ FCA AUTO THERMOSTAT FCM SEGUREZZA MANUALE FCM HANDUBERHITZUNGSSCHUTZ SC HEATING COOLING SELECT SC INVERTITORE CALDO FREDDO SC INVERSOR CALOR FRIO SC UMSCHALTER HEIZUNG KUHLUNG VF KALTWASSERS...

Page 31: ...si pr sence CF CABLAGE CLIENT Shunt a oter si presencia CF A1 A2 VERKABELUNG KUNDE CABLEADO CLIENTE Shunt in oter if presence CF Config Dip switch Hydronic Valves Mode management 1 2 3 4 5 6 7 O N 1 2...

Page 32: ...CH ELEMENT S CHAUFFANT S VF MOTEUR DE VANNE TOR VCH MOTEUR DE VANNE TOR FCA SECURITE AUTOMATIQUE 9 10 BU BN BN BU BN BU BK BU BN BN BK BK RD BU OPTION SCH MONTE POUR THERMOSTAT TAE20 MODELE MODEL MODE...

Page 33: ...NG COOLING SELECT SC INVERTITORE CALDO FREDDO SC INVERSOR CALOR FRIO SC UMSCHALTER HEIZUNG KUHLUNG VF KALTWASSERSCHIEBER WARMWASSERSCHIEBER BK BK BK BK BN BN BK BK BU BK BN BU AVEC RELAIS DE CHAUFFAGE...

Page 34: ...G KR RELE DI RISCALDAMENTO SB2 FL ANTI INTERFERENCE FILTER FL FILTRO ANTIDISTURBO FL FILTRE ANTIPARASITE BK GY WATER TERMINAL EC Mode management 1 Valves GN WH BN Shunt in oter if presence CF 2 S E 47...

Page 35: ...TERMOSTATO OPCION SCH SUBIDA PARA TAE20 TERMOSTATO AUFGERICHTETE OPTION SCH FUR THERMOSTAT TAE20 M KR RELAIS DE CHAUFFAGE SW SCH SONDE DE TEMPERATURE D EAU KR HEATER RELAY SW SCH WATER TEMPERATURE SE...

Page 36: ...TORE CALDO FREDDO SC INVERSOR CALOR FRIO SC UMSCHALTER HEIZUNG KUHLUNG V KALTWASSERSCHIEBER WARMWASSERSCHIEBER BK BK BK BK BN BK BK BN BU AVEC RELAIS DE CHAUFFAGE WITH HEATER RELAY KC BU BK BK BK BU W...

Page 37: ...L F ALLGENEIMER SCHUTZ F PROTECTION GENERALE Y MOTEUR DE VANNE EAU FROIDE CHAUDE SC INVERSEUR FROID CHAUD SC HEATING COOLING SELECT SC INVERTITORE CALDO FREDDO SC INVERSOR CALOR FRIO SC UMSCHALTER HEI...

Page 38: ...VALVULA FRIO CALO Y KALTWASSERSCHIEBER WARMWASSERSCHIEBER F GENERAL PROTECTION F PROTEZIONE GENERALE F PROTECCION GENERAL F ALLGENEIMER SCHUTZ F PROTECTION GENERALE Y MOTEUR DE VANNE EAU FROIDE CHAUD...

Page 39: ...VALVE CHANGE OVER TAE 20 CHANGE OVER TRM FA F CHAUFFAGE ELECTRIQUE VANNE DE REGULATION CHANGE OVER TAE 20 CHANGE OVER TRM FA D ELEKTROHEIZUNG REGELVENTIL CHANGE OVER TAE 20 CHANGE OVER TRM FA I RISCA...

Page 40: ...2 1 SW 7 8 6 2 L 1 N 2T S S SW TRM FA 3 4 5 6 7 8 9 10 4 N 7 3 2 1 8 6 2 L 1 N 2T S S TRM FA 3 4 5 6 7 8 9 10 4 N 7 3 2 1 8 6 2 L 1 N 2T S S TRM FA 3 4 5 6 7 8 9 10 4 N 7 3 2 1 8 6 2 L 1 N 2T S S TRM...

Page 41: ......

Page 42: ...es None As part of our ongoing product improvement programme our products are subject to change without prior notice Non contractual photos Systemair AC SAS Route de Verneuil 27570 Tilli res sur Avre...

Reviews: