Synway Information Engineering Co., Ltd
SMG-D Series Analog Gateway User Manual (Version 2.0.0)
Page 39
Starting Port
The starting serial number of the FXO port on the device in the batch setting.
Ending Port
The ending serial number of the FXO port on the device in the batch setting.
Starting SIP Account
The starting SIP account in the batch setting.
Starting Display Name
The starting displayname in the batch setting.
Starting Authentication
Password
The starting authentication password in the batch setting.
SIP Account Batch Rule
The rule for batch setting the SIP account, including
Increase
and
Decrease
two
options.
SIP Account Batch Step
Size
Sets the increase or decrease step size of the SIP account in the batch setting.
Display Name Batch Rule
The rule for batch setting the display name, including
Increase
,
Decrease
and
All
Same
three options.
Display Name Batch Step
Size
Sets the increase or decrease step size of the display name in the batch setting.
Authentication Password
Batch Rule
The rule for batch setting the authentication password, including
Increase
,
Decrease
and
All Same
three options.
Authentication Password
Batch Step Size
Sets the increase or decrease step size of the authentication password in the batch
setting.
Batch Rule of Bound
Number
The rule for batch setting the bound number, including
Increase
,
Decrease
and
Use the same number
three options.
Batch Step Size of Bound
Number
Sets the increase or decrease step size of the bound number in the batch setting.
Whitelist of FXO Out
Calls
Fill in the rule to match FXO outbound whitelisted number. Only those numbers
matching this rule will be allowed by the gateway to call out from the FXO port. The
default setting is null which means this feature is disabled..
After configuration, click
Save
to save the settings into the gateway, or click
Cancel
to cancel the
settings.
3.7.3 FXO Port Timer
The FXO Port Timer interface displays such information as the max call time limit for a single call,
the max call time limit for the total calls on each FXO port, as well as the timer clear cycle. Click
Modify for each port to modify the timer settings.
The table below explains the configuration items on the interface:
Item
Description
Port
Serial number of the FXO port on the device.
Unit
Sets the timing unit for the call. The actual call time will be calculated as the integral
multiple of the setting time. Take an example: supposed the setting time is 30s and
the actual call time is 72s, thus, the gateway will consider the call time as 90s.
Time Limit on a
Single Call
Sets whether to enable the time limit on a single call.
Max Call Time
Sets the maximum time length of a call.