Dear users, please go through the instructions in detail before the installation. Also, please hand the manual to
the actual operator of the machine and preserve it properly.
Drivers are precision electronic devices. For the safety of both operators and the machine, please ensure all
installations, tests and adjustments are operated by professional personnel. For the description with “DANGER”
,
“WARNING” and “CAUTION” in the manual, please read them in detail. If there are any concerns, please
contact our branches in your region. Our professionals are glad to be at your service. The following are the
guidelines you should comply with before finishing reading the complete manual:
⚫
The installing environment should be indoor and without water vapor, corrosive or flammable gas.
⚫
Implement the wirings according to the wiring diagram.
⚫
The grounding must be strictly implemented and follow the current National Electrical Code.
(References: NFPA 70: National Electrical Code,2005 Ed.)
⚫
Do not modify the wirings while the device is powered up.
1.
Safety Precautions
2.
Installation Notifications
The leakage current of an all-in-one driver is usually over 3.5mA. In accordance with
EN 61800 5-1, fixed installation is required.
The direction of the installation must comply with the regulations, otherwise it will
cause servo failure.
When installing the driver, the air intake and vent holes should not be sealed, and the
driver should not be tipped; otherwise it will cause malfunctions.
Do not install the driver near flammable materials.
Ensure every mounting hole is locked up when fixing the driver.
Ensure the installation surface can support the weight of the driver.
3.
Driver Interface Instructions
(Top View)
Driver Function
A
External Power Supply
Connect to 380V three-phase electrical power (RST).
B
Regenerative Resistor
External regenerative resistor connects to P and B.
C Machine Power Supply
Connect to motor and supply power (UVW).
3 sets in total, from the left to right are the 1
st
, the 2
nd
,
and the 4
th
axis.
D
MIII Serial
Communication Port
Connect to the host controller (MIII Signal).
Connect to the serial driver (MIII Signal).
E
Mini USB Port
Connect to personal computer.
F
I/O Signal Port
Connect to I/O equipment (the emergency stop,
indicator lights, etc.)
G
Encoder Feedback
From top to bottom are the 1
st
port to the 4
th
connecting to motor encoders.
4.
Controller Specifications (Unit: mm)
5.
Installation Specifications (Unit: mm)
⚫
Default Settings
(Top View) (Side View)
⚫
Recommended Arrangement for Heat Dissipation
For heat dissipation, operators may remove the original L-bracket on the bottom and
attach it to the middle.
The hole on the middle for installing opposite.
(Top View) (Side View)
Please pay extra attention to the instructions below while operating the product.
◼
Install the driver according to the instructions in the manual or it might cause damage to the
equipment.
◼
Do not operate the product in places exposed to water vapor, corrosive or flammable gases. It
might cause damage to the device, electric shocks, fire or explosion.
◼
Do not install the product at a temperature exceeding the specified range. It might cause
device damage or malfunctioning.
◼
The driver series are designed to control the motors. Do not touch the internal circuits or parts
while the driver is powered up.
◼
The internal circuit board of the driver contains CMOS ICs, which are vulnerable to static
electricity. Do not touch the circuit board with your hands before taking any precautions.
◼
The product has been certified by EN 61800-5-1/EN 61800-3. It is for use in industrial
environments.
◼
Do not apply the product to machines that might lead to casualties, device damage or system
shut down.
◼
Please cut off all the external device loads when powering up the driver for the first time in
case the built-in testing program starts running the motor immediately after power input. It
may be dangerous for the operators around.
◼
The driver is a precision instrument. Please prevent non-maintenance staff or
non-professional electronic control personnel from disassembling the device.
◼
Please apply the correct ground loop to prevent signal errors.
◼
Please separate the communication cable of the driver from all the other motor and power
cables with individual wiring ducks to prevent the controller from malfunction caused by large
noise interference.
◼
The driver adopts microcomputer design. Please install the driver in a safe area and keep the
area clean. Please keep iron shavings, wires, water, corrosive gas and liquid from the driver
to avoid malfunction.
◼
Please reserve at least 50mm in width for ventilation and heat dissipation.
◼
The grounding of the driver and machine tool system is necessary for leakage protection and
prevention of lightning strikes. Please ensure the driver and the machine tool system are
grounded properly before installing.
◼
The power system of the driver should meet the rated voltage. If the operating environment
provides an unstable voltage source, please apply a voltage stabilizer so that the driver can
function properly.
◼
Please turn off the power before plugging/unplugging the cables or modifying the wirings to
prevent electric shocks or damage to the driver.
◼
Please make sure all the terminals are in the correct positions while wiring to prevent the
driver from damage caused by wiring mistakes.
◼
Do not touch the terminals within 10 minutes after cutting off the power in case that the
residual voltage might cause electric shocks.
◼
Unload the driver after the driver is powered off after 30 minutes.