SET YOUR COMPUTER’S STATIC IP ADDRESS
PAGE
|
78
The Default Gateway field can be left blank.
Figure 4-41
I
nternet Protocol (TCP/IP) Properties dialog.
7.
Click
OK
to submit the changes.
Prepare the upgrade files
1.
Double-click the p250_Firmware_Upgrade.zip file
and extract the enclosed firmware upgrade
folder to the computer’s desktop.
2.
Double-click the firmware upgrade folder
to open it.
Connect to the p250 laser
1.
Remove DC power from the laser.
2.
Locate the Ethernet crossover cable in the ship kit and connect it between your computer and
the p250’s Ethernet port.
3.
Remove the Quick Start Plug from the p250’s User I/O connector.
4.
Apply 48 VDC power to the laser and wait 15 seconds for the firmware to initialize.
5.
If you have changed the p250’s IP address (the factory default is 192.168.50.50), you must change
it back. If not, proceed to the next section, Perform the firmware upgrade.
•
Launch your web browser, type the laser’s IP address, and then press Enter.
•
When the home page appears as shown in the following figure, click the Con-figure IP Address
link at the bottom of the page.
Summary of Contents for p250
Page 1: ...ENGINEERED BY SYNRAD p250 Laser User Manual...
Page 15: ...NOMENCLATURE CONTINUED PAGE 15 Nomenclature Continued Figure 1 2 Anatomy of a model number...
Page 27: ...EUROPEAN UNION EU REQUIREMENTS ROHS COMPLIANCE PAGE 27 Figure 2 3 p250 Declaration Document...
Page 40: ...RF POWER SUPPLY PAGE 40 Table 4 3 Dew point temperatures Continued...
Page 63: ...INPUT OUTPUT SIGNALS PAGE 63 Table 4 4 User I O pin descriptions Continued...
Page 84: ...P250 GENERAL SPECIFICATIONS PAGE 84 Table 4 5 p250 general specifications Continued...
Page 87: ...P250 OUTLINE MOUNTING DRAWINGS PAGE 87 Figure 4 47 p250 packaging instructions...
Page 93: ...OPERATIONAL FLOWCHART PAGE 93 Operational flowchart Figure 5 1 p250 operational flowchart...
Page 94: ...STATUS LED S PAGE 94 Status LED s Table 5 2 p250 Input Output LED Status Signals...
Page 105: ...INDEX PAGE 1 This page is intentionally left blank...