48-5 REAR PANEL
PAGE
|
35
Figure 3-5 48-5 Back panel controls and indicators.
48-5 rear panel
Power LED
– illuminates green when the Keyswitch is turned to the ON position (or when an OEM laser is
powered up) to indicate that power is applied to internal circuitry.
Lase LED
– illuminates red to indicate the lase mode of operation. If a tickle signal is present, the LASE LED
turns on after the five-second delay and becomes brighter as the PWM duty cycle is increased.
Keyswitch (Keyswitch models only)
– used to turn the laser on, off, and to reset faults. The key cannot be removed
when the Keyswitch is in the ON position.
Command (CTRL) Input
– accepts tickle and PWM Command signal inputs. The output of the UC-2000
Controller (or FH Series marking head) is attached to this connector. DC Power Cables – red (+) and black
(–) DC Power input cables are manufactured from #12 AWG (48-1/48- 2) or #8 AWG (48-5) wire and
measure 1.1 meters (3.5 feet) in length.
DB-9 Connector
– provides an interconnection for message, fault shutdown, remote interlock, remote
keyswitch, and interface signals. Refer to the DB-9 connections section in the Technical Reference section
for information on pin assignments and function.
Summary of Contents for Novanta 48 Series
Page 1: ...ENGINEERED BY SYNRAD 48 Series User Manual...
Page 29: ...EUROPEAN UNION EU REQUIREMENTS ROHS COMPLIANCE PAGE 29 Figure 2 2 Declaration Document...
Page 40: ...SETTING COOLANT TEMPERATURE PAGE 40 Table 4 1 Dew Point Table F temperatures...
Page 70: ...TECHNICAL DRAWINGS PAGE 70 Figure 4 16 Model 48 5 package outline and mounting dimensions...
Page 71: ...TECHNICAL DRAWINGS PAGE 71 Figure 4 17 Model 48 1 packaging instructions...
Page 72: ...TECHNICAL DRAWINGS PAGE 72 Figure 4 18 Model 48 2 packaging instructions...
Page 73: ...TECHNICAL DRAWINGS PAGE 73 Figure 4 19 Model 48 5 packaging instructions...
Page 74: ...TECHNICAL DRAWINGS PAGE 74 Figure 4 20 FLMK 1A 10W fan shroud packaging instructions...
Page 82: ...OPERATIONAL FLOWCHART PAGE 82 Operational flowchart Figure 5 1 48 series operational flowchart...
Page 85: ...STATUS LEDS PAGE 85 Status LEDs Table 5 3 48 series Input Output LED Status Signals...