Section II
General Product Information
006-0007068 UPS-1500-S-2S Guide
Rev E
12 of 60
09/10/20
Electrical Characteristics
INPUT CHARACTERISTICS
Operating AC Input
Voltage
80-265 Vrms*
Frequency
47-65 Hz
(47-800 Hz Optional)
Input Power Factor
>0.98 at 47-65 Hz
>0.97 at 400 Hz
>0.93 at 800 Hz
Maximum Input Current Continuous
20 A
(full load, 85 Vrms)
AC Input Circuit Breaker Rating
25 A
(* Power Derating to 80% below 90 Vrms)
Operating DC Input (Optional)
Voltage
22-33 V
Continuous Maximum Input Current
62 A
(full load, 22 V)
Transient Maximum Input Current
75 A
OUTPUT CHARACTERISTICS
Total Output Power Continuous
1250 W (1500 VA)
Maximum DC1 Output Power
510 W
Maximum DC2 Output Power
1250 W
(Note: Available AC power is reduced by power delivered to the DC output)
AC Output
AC Output Waveform
Pure Sinusoidal
Voltage
115 Vrms ± 3%
230 Vrms ± 3%
Frequency
60 Hz ± 0.5%
50 Hz ± 0.5%
400 Hz ± 0.5%
Peak Load Current
26 A (115 Vrms)
13 A (230 Vrms)
Load Power Factor
0-1.0
(leading or lagging)
Total Harmonic Distortion
2%
(1000 W resistive load)
DC1 Output (optional)
Voltage Regulation (Over Load & Temperature) ± 3%
Common Voltage/Power combinations (DC1)
12 V at 42 A =504 W
(Other Options Available)
15 V at 34 A =510 W
24 V at 21 A =504 W
28 V at 18 A =504 W
40 V at 12.5 A =500 W
50 V at 10 A =500 W
DC2 Output (optional)
Voltage Setpoint
± 3%
No Sharing
Voltage Regulation (Over Load & Temperature) -2%
Common Voltage/Power combinations (DC2)
50 V at 20 A =1000 W
24 V at 50 A =1200 W
28 V at 44.6 A =1250 W
Droop Share
(Output droops vs. load to allow passive sharing among modules.)
24 V Option
Voltage Regulation (Over Load & Temperature) -15%
26 V at 0 A
22 V at 50 A =1100 W
28 V Option
Voltage Regulation (Over Load & Temperature) -13%
30 V at 0 A
26 V at 48.1 A =1250 W
Specifications subject to change without notice.
ENVIRONMENTAL CHARACTERISTICS MIL-STD-810G
Temperature Methods 501.5, 502.5
Operating Temperature
-20 °C — +50 °C
Storage Temperature
-40 °C — +65 °C
Altitude Method 500.5
Operating
0 - 18,000 ft
Non-operating
0 - 40,000 ft
Environmental Tests
Shock/Drop
Method 516.6, Procedures 1,4,6
Temperature Shock
Method 503.5, Procedure 1
Vibration
Method 514.6, CAT 5, 7, 8, 9, 24
Fungus
Method 508.6
Salt Fog
Method 509.5
Sand and Dust
Method 510.5, Procedures 1,2
Rain
Method 506.5 Procedure 1
EMI
MIL-STD-461F
Humidity
Method 507.5 Procedure 2
Mechanical Vibration of Shipboard Equipment Method 528 Procedure 1
RELIABILITY CHARACTERISTICS MIL-HDBK-217F
MTBF 100 kHrs
MIL-217F Ground Benign, Ta=25 °C
ELECTROMAGNETIC CAPABILITY MIL-STD-461F
CE101
30 Hz - 10 kHz
CE102
10 kHz - 10 MHz
CS101
30 Hz - 150 kHz
CS106
10 kHz - 40 GHz
CS114
10 kHz - 200 MHz
CS116
10 kHz - 100 MHz
RE101
30 Hz - 100 kHz
RE102
10 kHz - 18 GHz
RS101
30 Hz - 100 kHz
RS103
2 MHz - 40 GHz
* Regarding MIL-STD-461 CE-101, the 50 uH series inductance of a standard LISN
adversely affects the input ripple of the UPS (DC input only). Such a large series
source inductance (50 uH in each power lead) is not generally encountered in a
28 V DC source of such high power rating. Therefore, testing for CE-101 (DC input)
was conducted with 3 different configurations: two using 50 uH LISNs and a 54 mF
capacitor connected across the input to the UPS, and one using 5 uH LISNs for
which no additional capacitor was added.
These configurations all passed CE-101 for all frequencies.
MECHANICAL CHARACTERISTICS
Chassis
Chassis Size
17.00”W x 13.80”D x 3.40”H
Case Material
Aluminum
Total Weight
33 lbs. (with chassis & battery)
Connectors
AC Input Connector
MS3470L14-4P
User I/O Ports
HD DB15 Female
Configuration I/O Port
HD DB15 Male
Ethernet Port
Amphenol RJF22N00, Code B
DC Input Connector
MS3470L18-8P
AC Output Connector
MS3470L14-4S
DC1 Output Connector
MS3470L14-4SW
DC2 Output Connector
MS3470L18-8S
Cooling Exhaust Fans
Sound Pressure Level (SPL)
54 dB(A)
Air Flow
0.67(m
3
/min) 23.7 CFM
Two fans in system, above specs are for each fan separately.