Symmons SLC72121.2 Operation & Maintenance Manual Download Page 1

1

Model Number

SLC72121.2

Specification

Modifications

Warranty

Limited Lifetime

 - to the original end purchaser in 

consumer installations.

5 Years

 - for commercial installations.

Refer to www.symmons.com/warranty for complete 
warranty information.

Bramwell Centerset Faucet

Compliance

Bramwell Centerset Faucet

Operation & Maintenance Manual

SLC72121.2

Two handle centerset faucet includes lift rod, pop-up drain
assembly and replaceable hot and cold cartridges.  Faucet 
features 1.2 gpm (4.5 L/min) aerator with aerator removal 
key. Components made from metal and plastic materials 
plated in standard polished chrome finish.  

Dimensions

Measurements

A

9 5/16”, 237 mm

B

6 3/4”, 171 mm

C

7 1/2”, 191 mm

D

4”, 102 mm

E

4 3/8”, 111 mm

F

2 3/4”, 70 mm

G

4”, 102 mm 

H

2 13/16”, 71 mm

I

Max. 1”, 25mm

J

1/2” - 14 NPSM

K

Min. 1 1/8”, 29 mm

Max. 1 5/8”, 41 mm

A
B

C

D

E

F

G

H

I

J

K

Note: 

Dimensions are subject to change without notice.

-STN

Satin nickel finish

Certified by
CSA Group

-ASME A112.18.1/CSA B125.1
-NSF/ANSI 372, NSF/ANSI 61.9
-WaterSense 1.2 gpm (4.5 L/min)

Summary of Contents for SLC72121.2

Page 1: ...embly and replaceable hot and cold cartridges Faucet features 1 2 gpm 4 5 L min aerator with aerator removal key Components made from metal and plastic materials plated in standard polished chrome fin...

Page 2: ...Cartridge RL 076 D Lift Rod RL 153 E Aerator Key FLR 102 1 2 F Hardware Kit RL 151 G Pop Up Drain RL 117 A B D F E G C Tools Required for Installation Adjustable Wrench Allen Wrench 3 32 Screwdriver...

Page 3: ...ion Maintenance Manual SLC72121 2 If replacing an older faucet ensure water supply is turned OFF before removing then turn faucet control valve ON to relieve water pressure 1 2 Supply hoses not includ...

Page 4: ...mons com gethelp symmons com ZV 3011 REV B 122215 Maintenance Cartridge Replacement Bramwell Centerset Faucet Operation Maintenance Manual SLC72121 2 1 3 Care and Cleaning Clean finished trim area wit...

Page 5: ...tico y cartuchos reemplazables para fr o y caliente La llave cuenta con un aireador de 1 2 gpm 4 5 L min con llave de eliminaci n del aireador Los componentes est n hechos de metal y pl sticos recubi...

Page 6: ...a fr a RL 076 D Varilla de levan tamiento RL 153 E Aireador y llave FLR 102 1 2 F Juego de her rajes RL 151 G Ensamblaje de desag e RL 117 Herramientas requeridas para la instalaci n Llave ajustable L...

Page 7: ...reemplazando una llave m s vieja aseg rese de que el suministro de agua est CERRADO antes de quitarla y despu s gire la v lvula de control de la llave a ABIERTO para aliviar la presi n de agua 1 2 Ma...

Page 8: ...om ZV 3011 REV B 122215 Mantenimiento Reemplazo del cartucho de la v lvula Llave central Bramwell Manual de operaci n y mantenimiento SLC72121 2 Limpie el rea terminada con una tela suave usando agua...

Page 9: ...rtouches rempla ables d eau chaude et froide Le robinet pr sente un a rateur de 1 2 g m 4 5 l min avec une cl d enl vement d a rateur Composantes fabriqu es de m tal et plastic mat riaux plaqu s de fi...

Page 10: ...e RL 076 D Tige de levage RL 153 E A rateur et cl FLR 102 1 2 F Ensemble de mat riel RL 151 G Drain soulevable RL 117 Outils n cessaires pour l installation Cl ajustable Cl Allen 3 32 Tournevis Ruban...

Page 11: ...C72121 2 Si vous remplacez un ancien robinet assurez vous que l alimentation d eau est ferm e avant de retirer puis tournez la soupape de contr le du robinet ON pour lib rer la pression d eau 1 2 Boya...

Page 12: ...com ZV 3011 REV B 122215 Entretien Remplacement de cartouche Robinet monopi ce Bramwell Manuel de fonctionnement et d entretien SLC72121 2 Nettoyer la zone de garniture finie avec un linge doux en ut...

Reviews: