Symmons Origins SLC-9610-1.5 Operation & Maintenance Manual Download Page 1

Origins

®

-0.5

0.5 gpm (1.9 L/min) aerator

-1.0

1.0 gpm (3.8 L/min) aerator

-G

Grid drain

-STN

Satin Nickel finish

Model Numbers

Two Handle Centerset Lavatory Faucet

Operation & Maintenance Manual

SLC-9610-1.5, SLC-9612-1.5

Two handle centerset lavatory faucet featuring a 
4” mounting configuration.  Includes ceramic cartridges, 
1/2” IPS inlet connections, 50/50 drain assembly and 
standard 1.5 gpm (5.7 L/min) aerator. Components made 
from metal and nonmetallic materials plated in standard 
polished chrome finish.

Specification

Warranty

Limited Lifetime

 - to the original end purchaser in 

consumer/residential installations.

5 Years

 - for industrial/commercial installations.

Refer to www.symmons.com/warranty for complete 
warranty information.

Compliance

c

Certified by

IAPMO R&T

Dimensions

Note: 

Dimensions subject to change without notice.

Modifications

Note: 

Append appropriate -suffix to model number.

CG

CG

SLC-9610-1.5

Origins Two Handle Centerset Lavatory Faucet 
Less Rod

SLC-9612-1.5

Origins Two Handle Centerset Lavatory Faucet

-NSF/ANSI 372, NSF/ANSI 61.9
-ASME A112.18.1/CSA B125.1
-WaterSense 1.5 gpm & 1.0 gpm

Measurements

A

8 7/8”, 225 mm

B

6”, 152 mm 

C

4”, 102 mm

D

3 3/4”, 95 mm

E

Deck Thickness Ref.

Max. 1 1/4”, 32 mm

F

Hole Size

Min. Ø 1”, 25 mm

Max. Ø 1 1/8”, 29 mm

G

(2x) Hole Size

Min. Ø 1 1/8”, 29 mm

Max. Ø 1 1/4”, 32 mm

H

3 1/8”, 79 mm

I

1 5/8”, 41 mm

J

4 1/4”, 108 mm

K

1 3/4”, 44 mm

L

1/2-14 NPSM

C

C

D

D

E

E

JJ

K

K

G

G

B

B

A

A

FF

H

H

II

LL

WARNING:

 This product can expose you to chemicals 

including lead, which is known to the state of California to 
cause cancer, birth defects, or other reproductive harm.  
For more information, go to www.P65Warnings.ca.gov.

Summary of Contents for Origins SLC-9610-1.5

Page 1: ...ty information Compliance c Certified by IAPMO R T Dimensions Note Dimensions subject to change without notice Modifications Note Append appropriate suffix to model number CG CG SLC 9610 1 5 Origins T...

Page 2: ...dge RL 222H F Cold Cartridge RL 222C H Aerator RL 240 1 5 1 5 RL 240 1 0 1 0 RL 240 0 5 0 5 I J Mounting Hardware RL 221 K 50 50 Drain Assembly RL 223 SLC 9612 1 5 L Grid Drain P 26 SLC 9610 1 5 Tools...

Page 3: ...3 K2 K7 PLUMBER PUTTY OPTIONAL K3 K4 K5 K6 4 Turn tail piece K7 and flange K2 so pivot is facing toward faucet Pull assembly down into drain hole Secure hardware from below sink Install stopper K1 in...

Page 4: ...y lines to 1 2 IPS inlet connections on faucet body G Using a wrench finish with one half turn DO NOT overtighten Maintenance 1 Turn off water Loosen and remove handle set screw D handle B nut C and o...

Page 5: ...s 5 a os para instalaciones industriales comerciales Consulte www symmons com warranty para obtener informaci n completa sobre la garant a Cumplimiento c Certified by IAPMO R T Dimensiones Modificaci...

Page 6: ...5 1 5 RL 240 1 0 1 0 RL 240 0 5 0 5 I J Hardware de montaje RL 221 K Ensamble del desag e 50 50 RL 223 SLC 9612 1 5 L Desag e de rejilla P 26 SLC 9610 1 5 Nota Anexar STN al n mero de pieza para el ac...

Page 7: ...K7 PLUMBER PUTTY OPTIONAL K3 K4 K5 K6 4 Gire la rejilla K7 y la brida K2 para que el pivote mire hacia el grifo Jale el ensamble hacia abajo dentro del orificio de desag e Asegure el hardware al ensam...

Page 8: ...grifo G y apri telas a mano Utilizando una llave termine con media vuelta NO apriete demasi ado Mantenimiento 1 Cierre el agua Afloje y retire la manija Tornillo de fijaci n D mango B tuerca C y el c...

Page 9: ...stallations commerciales et industrielles Se reporter au site www symmons com warranty en an glais pour l information compl te concernant la garantie Conforme c Certified by IAPMO R T Dimensions Modif...

Page 10: ...5 1 5 RL 240 1 0 1 0 RL 240 0 5 0 5 I J Mat riel de xation RL 221 K Ensemble pour drain 50 50 RL 223 SLC 9612 1 5 L Drain de la grille P 26 SLC 9610 1 5 Remarque Juxtaposer le STN au num ro de pi ce...

Page 11: ...serrez la main 2 3 K2 K7 PLUMBER PUTTY OPTIONAL K3 K4 K5 K6 4 Tournez la pi ce de raccordement K7 et la bride K2 afin que le pivot soit face au robinet Tirez l ensemble dans le trou de drain age Fixe...

Page 12: ...du robinet et serrer la main A l aide d une cl terminer avec un demi tour NE PAS trop visser Co t d entretien 1 Couper arriv e d eau Desserrer et retirer la vis de r glage poign e D poign e B l crou...

Reviews: