1
TimeSource 3000
139
TL1 Reference
097-72000-02 Issue 6: October 2003
2
5
3
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
44
Enter Equipment
This command puts optional inputs in service, and causes the selected input to be monitored.
Additionally, this command can cause an input to be ensembled. All in-service inputs are
monitored. The Delete Equipment command must be used to take an input out of service.
The command format is:
ENT-EQPT:[<tid>]:<aid>:<ctag>[:::<spec_block>];
Aid
Value
Item Addressed
RO-a
a=A
Remote oscillator A input monitor
a=B
Remote oscillator B input monitor
SPAN-a
a=A
T1 span A input monitor
a=B
T1 span B input monitor
Summary of Contents for TimeSource 3000
Page 1: ...TimeSource 3000 GPS Primary Reference Source 097 72000 02 Issue 6 October 2003 ...
Page 47: ...3 Chapter Installation This chapter provides the steps required for installation and power up ...
Page 107: ...Chapter 4 TL1 Reference This chapter provides information for using the TL1 language ...
Page 203: ...Chapter 6 Specifications This chapter provides equipment specifications ...