098-00028-000 Revision F – May, 2012
TimeProvider 5000 User’s Guide 133
Chapter 3
TimeProvider 5000 CLI Command Set
set gnss
Use this command to configure the GNSS port state, priority, positioning mode,
mask, track mode, PQL state, and PQL value. Possible track modes for the GNSS
port are:
forced GPS
forced Beidou
GPS priority over Beidou, switch automatically
Beidou priority over GPS, switch automatically
Command Syntax:
To change GNSS mode on the GNSS port:
set gnss mode { auto | manual [latitude <lat-value>
longitude <lon-value> height<height-value>]}
– Position can only be provisioned manually when GNSS mode is “manual”.
Where
Latitude is in the format N|Sddd:mm:ss.sss, for example:
N37:22:45.123
S48:33:67.456
Longitude is in the format E|Wddd:mm:ss.sss, for example:
W121:55:36.123
E157:33:47.456
Height is in meters with one digit after the decimal point, for
example:
17.5
To change GNSS track mode on the GNSS port:
set gnss track-mode { beidou | gps | priority_beidou |
priority_gps}
To enable or disable GNSS on the GNSS port:
set gnss state {enable|disable}
To set the priority on the GNSS port
set gnss priority <priority-value>
To set the GNSS mask value
Note:
Symmetricom recommends that the Auto mode be used. Any
error in the manually-specified system position will generate timing
errors.
Summary of Contents for TimeProvider 5000
Page 12: ...Table of Contents 12 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 16: ...List of Figures 16 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 20: ...List of Tables 20 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...
Page 56: ...56 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 Chapter 1 Overview Alarms ...
Page 534: ...Index W W 534 TimeProvider 5000 User s Guide 098 00028 000 Revision F May 2012 ...