098-00172-000 Revision A – December, 2009
TimeProvider 500 2.0 User’s Guide
101
Chapter 4 CLI Commands
Set Output Commands
Response:
Alarm 3 is disabled
Set Output Commands
The
set output
commands enable you to create settings and conditions for output
signal behavior of the TimeProvider 500.
Figure 4-3.
Set Output Commands
set output freerun
This command sets the specific output behavior of TimeProvider 500 when it is in
freerun mode. The following parameters are used when specifying output behavior:
on
–using this setting will use the
set output signaltype
when TimeProvider
500 is in freerun mode. See
.
ais
–using this setting will cause the appropriate Alarm Indication Signal (AIS) to
be generated when in freerun mode. If
set output signaltype
is set to
disable, no AIS output will be generated.
squelch
–using this setting causes the outputs to be turned off when in freerun
mode regardless of the
set output signaltype
settings
.
Syntax:
set output freerun { ais | on | squelch }
Default:
Note
: To see changes made, use the CLI command,
show
alarm-config
set output commands
ais
on
squelch
holdover
freerun
ais
on squelch
hbd3
enable
disable
clk_2048
e1_ais
e1_cas
e1_cas4
e1_ccs
e1_ccs4
disable
t1_sf
t1_esf
clk_1544
t1_iso_pulse
out3
out4
out1
out2
pps-offset
pps-width
pps-mode
standard
coupled
1pps
clk_2048
e1_ais
e1_cas
e1_cas4
e1_ccs
e1_ccs4
disable
t1_sf
t1_esf
clk_1544
t1_iso_pulse
Summary of Contents for TimeProvider 500
Page 10: ...Table of Contents 10 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 12: ...List of Figures 12 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...
Page 146: ...146 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 T1 Format ...
Page 174: ...Index W W 174 TimeProvider 500 2 0 User s Guide 098 00172 000 Revision A December 2009 ...