Issue 2: Sep 99
TMSL 097-44018-26
Page 53
COMMAND CODE: ENT-INVENTORY
PURPOSE
ENTER INVENTORY
This command is for nonstandard cards and standard cards without a database (LTI, ST2, ST2E, ST3,
ST3E, TNC, TNC-E, and LNC). This command is used to enter the card name, part number, CLEI code,
serial number, hardware revision, and software revision into the system database for each slot equipped
with a nonstandard card. All cards entered with this command are nonstandard because they do not con-
tain a database and cannot communicate with the MIS card. (Standard card information is communicat-
ed to the MIS card when the ENT-EQPT command is used for that card.) For a list of standard cards,
refer to Table C.
Note: Inventory information appears on the front panel of the card. If any particular parameter informa-
tion is not available, leave that parameter blank.
INPUT FORMAT
ENT-INVENTO-
RY:[<tid>]:<aid>:<ctag>::[<card>],[<part>],[<clei>],
[<serial>],[<hardware_revision>],[<software_revision>];
Caution:
The letter/number combinations “NO”, “E1”, “E2”, and “E3” cannot be entered
alone
in any field in this command. These combinations can be used if additional characters are en-
tered before or after these combinations.
A maximum of 20 characters is allowed for each of the following parameters: <card>,<part>,<clei>,
<serial>,<hardware_revision>, and <software_revision>. Parameters not entered will remain blank
(null). The parameter values in the table below are as follows:
a
= 1–2
b
= 1–12
aid
card
INPUT-a
ACI
CI
CI-EA
ECI
PROT
MCA-5