COMMAND CODE: SET-TH-PORT
PURPOSE
SET THRESHOLD PORT
This command sets the threshold level for a monitored parameter. When the parameter exceeds the
threshold value, an automatic message is sent. The threshold may apply to one or more units. One com-
mand is required for each threshold setting.
INPUT FORMAT
SET-TH-PORT:[<tid>]:<aid>:<ctag>::<montype>,<thlev>;
The parameter values in the table below are as follows:
a
= 1–2
c
= 2
e
= 2–4 (c > b)
b
= 1–2 or ALL
d
= 1–4 or ALL
f
= 1–11
Note:
Only in-service (restored) ports are sampled; therefore, the BPV or CRC counts entered to obtain
a desired error rate depends on the number of in-service ports. Enter a BPV or CRC count from the table
below based on the desired error rate and the number of ports in service as the <thlev> parameter in the
command.
aid
montype
thlev
meaning
DCIM-a-b
BPV
1–32767
bipolar violations (see note below)
CRC
cyclic redundancy check errors
MRC-a-d[&&-e]
BPV
1–32767
bipolar violations (see note below)
CRC
cyclic redundancy check errors
Error Rate
BPV or CRC counts for a T1 signal
1 port in
service
2 ports in
service
3 ports in
service
4 ports in
service
1 x 10
-8
14
7
5
4
1 x 10
-7
139
70
46
35
1 x 10
-6
1390
695
464
348
1 x 10
-5
13896
6948
4632
3474
2.35 x 10
-5
32767
16384
10922
8192