110 TimeCreator 1000 User’s Guide
097-93100-01 Revision C – February, 2010
Chapter 5 Provisioning
Saving and Restoring Provisioning Data
Restarting TimeCreator 1000’s IMC Card
The system can be restarted via a command. Since reference output signals will be
lost, it is not recommended to restart the entire system unless required. Only the
admin user can issue the reboot command. The following command restarts the
IMC card:
Example
Type
reboot imc
and press
Enter
.
Saving and Restoring Provisioning Data
Symmetricom recommends that you keep an electronic version and/or a written
version of the provisioning changes you make to the TimeCreator 1000.
Backing up Provisioning Data
Configuration of the IOC and IMC is independent. Both the IOC and IMC can be
used to store configuration files.
Backup Current Configuration
To backup up the current configuration, use the command “set configuration
backup”.
Example
Type
set configuration backup
and press
Enter.
Backup Current IOC Configuration to IMC Card
To backup the current IOC configuration in the IMC card, use the command “set
configuration backup IOC”:
Example
Type
set configuration backup IOC
and press
Enter
.
Note:
IMC configuration changes are not saved automatically, so it is
necessary to use the command “set configuration backup IMC” to
explicitly save the changes. Failure to save changes with this
command will result in IMC configuration changes being lost after the
IMC reboots.