166 TimeHub 5500 User’s Guide
097-55501-01 Revision M – January 2009
Chapter 4 Testing and Configuring the TimeHub
Provisioning Inputs on a Master Shelf
9. Set Framing for enabled DS1 inputs, if needed. DS1 inputs may have either D4
(also known as SF) or ESF framing. TimeHub defaults DS1 inputs to expect D4
framing, so if you have ESF inputs the setting needs to be changed.
The general TL1 format for setting framing is:
ED-SYNC::CLK-a:<ctag>:::ESF=b;
where a = 0 – 4 to identify the input (PRS = 0)
b = Y (ESF framing) or N (D4 framing)
To set input 2 framing to ESF, issue the command:
ED-SYNC::CLK-2:SV382:::ESF=Y;
10. Configure inputs to use SSM, if desired. If you have ESF-framed DS1 inputs
providing SSM messages that you want to use as part of the input qualification
process, follow steps 10 and 11 to enable the SSM capability. By default, SSM is
not used for qualifying inputs. If you do not want to use SSM for input
qualification, skip to step 12.
Select SSM to be used as an input qualification criteria by issuing the command:
ED-EQPT::CLK:SV41:::SYNCMDE=SSM;
11. Set Bridged mode for enabled DS1 inputs, if needed. Generally, DS1 inputs
connected to TimeHub will be terminated at the input. However, if the reference
signal is bridged (which means it will be nominally 20 dB lower in amplitude), the
bridged selection should be set for any such input. The default setting is that
bridged inputs are not expected for inputs 1 – 4.
The general TL1 format for bridged setting is:
ED-SYNC::CLK-a:<ctag>:::BRIDGED=b;
where a = 1 – 4 to identify the input whose bridged state is being set
b = Y for Bridged expected, N for Bridged not expected (i.e., terminated)
To set input 1 to expect a bridged signal level, issue the command:
ED-SYNC::CLK-1:SV385:::BRIDGED=Y;
To retrieve the bridged setting for input 1, issue the command:
RTRV-SYNC::CLK-1:SV386:::PARAMETER=BRIDGED;
To disallow the use of SSMs as input qualification criteria, issue the command:
ED-EQPT::CLK:SV43:::SYNCMDE=AUTO;