![Symmetricom TimeHub 5500 User Manual Download Page 163](http://html.mh-extra.com/html/symmetricom/timehub-5500/timehub-5500_user-manual_1419592163.webp)
097-55501-01 Revision M – January 2009
TimeHub 5500 User’s Guide 163
Chapter 4 Testing and Configuring the TimeHub
Provisioning Inputs on a Master Shelf
On the Configuration Input tab, use the
Read SSM
row to enable actual SSM
decoding for ESF-framed DS1 inputs. Note that D4-framed DS1 inputs and the
PRS input do not show the
Read SSM
selection since they are not capable of
SSM decoding.
To continue provisioning a Master shelf, continue at
Using TL1 Commands
Use this procedure to provision the inputs for a Master shelf. If you are provisioning
inputs for a Remote shelf, see
Provisioning Inputs on a Remote Shelf
The DS1 inputs for SSM decoding are connected to the wire-wrap pins labeled
“DS1 TERM IN”, rows 1 through 4 on the Input/Alarm Connector module (refer to
and
).
The following procedure describes how to set up the DS1 input 1 as an SSM
source. The procedure is identical for DS1 inputs 2 through 4 by replacing any
references to input 1 with the appropriate input number.
1. Connect the DS1 signal to be used as a source of SSM to the Input/Alarm
Connector module pins labeled “DS1 TERM IN” on the row labeled “1” (refer to
and
). Typically, this can be any ESF-framed DS1 output
from the Main shelf. Such a signal always contains SSM encoding reflecting the
current synchronization quality level of the Main shelf.
2. Verify that the “E” LED on the Clock card is lit (if there are two Clock cards in the
shelf, observe this LED status on either one). For the DS1 input 1 signal, this is
the third row of LEDs in the INPUTS section. Note that this row is labeled
DS1-1, indicating that it is providing status on any signal connected to the DS1
input 1 pins on the input module. The “E” LED, when lit, indicates that this input
can be used for SSM decoding. If the “E” LED is not lit, that input will not be
used for SSM decoding even if the input is present and valid.
3. If the “E” LED is not lit, issue the following command:
ED-SYNC::CLK-1:SC1:::ENABLE=Y;
The ”E” LED should light after you issue this command. To enable DS1 input 2,
change
CLK-1
to
CLK-2
.
4. Verify that the input is enabled by issuing the following TL1 command:
RTRV-SYNC::CLK-1:SV16:::PARAMETER=ENABLE;
5. If the connected DS1 signal is carrying valid SSM, the “Q” LED will light within a
few seconds. This LED, when lit, indicates that the input is qualified as providing
decodable SSM information.