Chapter 3 Configuring
Configuring TP5000 Module Using TimeMonitor PDV
11.Click the
Probe Address
button to set the new IP address for the selected
Ethernet port on the TP5000 probe module. Skip this step if the IP address for
the port was previously configured to the desired value.
12.Click the
Logout
button.
Setting for Free-Run of Internal Rb Clock
The default Time of Day (TOD) source is GPS, but the TP5000 module can be
configured to use the free-running internal Rb clock as reference. The TOD souce
must be set to System, with no input signals on the programmable input ports.
1. Login at the Admin or Config-user level (see
Logging In
, on page 48).
2. Type
set tod-source sys
and press
Enter
.
3. Type
show tod-source
and press
Enter
to verify the TOD source.
4. Type
set input state port1 disable
and press
Enter
.
5. Type
set input state port2 disable
and press
Enter
.
6. Type
sync tod-source now
and press
Enter.
Setting the System Date Time and Time Offset
The TP5000 probe module Time of Day can be set either by an external source, or
manually with the “set clock” command. You can set the time and date only in the
system tod-source mode, but if the TOD source has been set to GPS (default), it is
not possible to set the time manually.
Example
1. Login at the Admin or Config-user level (see
2. Type
show tod-source
and press
Enter
to check the TOD source.
3. Type
set tod-source sys
and press
Enter
.
4. Type
set clock date-time <value>
and press
Enter
.
Enter the value in
format yyyy-mm-dd,hh:mm:ss.
5. Type
sync tod-source now
and press
Enter.