Chapter 2 TL1 Reference
Retrieve Input Status
68
SSU-2000e Technical Reference
12713140-003-2 Revision E.01 – January 2007
Retrieve Input Status
This command returns the condition (current operating mode and readings) of the
input ports.
Syntax
RTRV-STATUS-INPUT:[tid]:[aid]:ctag;
Response Format
One line is returned for each module [or port] designated by the aid.
^^^"aid:mstat,pstate,(pha),(phb),pql" <cr lf>
where:
aid
= module or port access identifier
mstat
= module status {OK | DIS | FLT}
pstate
= the port state {OK | DIS | FLT}
pha
and
phb
= current 1-second phase values in nanoseconds, or NA if not
available
pql
= current pql level (read or provisioned) being reported by the port, if
available. If pql = 0 , then the pql is not applicable for that port.
Example
SSU_2000 06-03-08 20:28:19
M 100 COMPLD
"S1A03-01:OK,OK,(-29),(-8),2"
"S1A04-01:OK,OK,(-20),(-72),4"
"S1A05-01:OK,DIS,NA,NA,4"
;
Parameter
Value
Description
[aid]
ALL
Retrieves the parameters from all Input modules in the
shelf.
S1Ay[-z]
Retrieves parameters from the specified Input module [or
port].