Chapter 2 TL1 Reference
Retrieve Alarm Parameters
40
SSU-2000e Technical Reference
12713140-003-2 Revision E.01 – January 2007
Retrieve Alarm Parameters
This command returns the alarm settings for the specified module, or ALL alarms if
no aid is specified.
Syntax
RTRV-PRMTR-ALARM:[tid]:[aid]:ctag;
Response Format
^^^"aid:almnum,level,startdelay,cleardelay"<cr lf>
where:
aid
= module or port access identifier
almnum
= alarm number
level
= Ignore, Report, Minor, Major, or Critical: [IGN|RPT|MIN|MAJ|CRT]
startdelay
= delay time or errored seconds count for start of the alarm
cleardelay
= cleared seconds count for clearing of the alarm. Delay numbers
are reported only if they are settable for the alarm; otherwise they are reported as
IMMED (immediate).
Related Commands
Parameter
Value
Description
[aid]
ALL
Retrieves all the alarm parameters from the shelf.
SxAy[-z]
Retrieves alarm parameters from the specified module [or
port].