12713140-003-2 Revision E.01 – January 2007
SSU-2000e Technical Reference 211
Chapter 3 ICS Command Reference
PHASE
PHASE
Use this command to access phase history data.
Level 0
Not applicable
Level 1
PHASE [xAy[-z]][{A|B}]{T1|T100|T1K|T10K}[count]
Use this command to view the 100 / 1000 / 10 000 second phase history
information. One-second phase is not stored in phase history. If you do
not provide a parameter, phase information displays for the selected
clock to all inputs that last stored the point.
Example
SSU_2000->phase
The current phase values with T1:
1A03-01 PhA:2001-05-24T18:29:00, 3
1A04-01 PhA:2001-05-24T18:29:09, 1
1A04-02 PhA:2001-05-24T18:29:09, 1
1A04-03 PhA:2001-05-24T18:29:09, 3
1A05-01 PhA:2001-05-24T18:29:12, 5
1A09-01 PhA:2001-05-24T18:29:12, 1
1A09-02 PhA:2001-05-24T18:29:12, 2
1A09-03 PhA:2001-05-24T18:29:12, NA
1A10-01 PhA:2001-05-24T18:29:13, 1
1A10-02 PhA:2001-05-24T18:29:13, 3
1A10-03 PhA:2001-05-24T18:29:13, 2
1A11-01 PhA:2001-05-24T18:29:14, NA
1A11-02 PhA:2001-05-24T18:29:14, 2
1A11-03 PhA:2001-05-24T18:29:14, NA
Level 2
Same as Level 2 operation, with the following additions:
PHASE [xAy[-z]] ZERO [{A|B}]
Use this command to zero the phase error for the desired input port. If
you do not provide a parameter, all inputs on both clocks are zeroed.
Level 3
Same as Level 2 operation
Level 4
Same as Level 3 operation
Remarks None
Related
RestrictionsNone