12713140-003-2 Revision E.01 – January 2007
SSU-2000e Technical Reference 175
Chapter 3 ICS Command Reference
COMM
COMM
Use this command to view and change the current communication port settings.
Level 0
Not applicable
Level 1
COMM [{L|A|B}]
Use this command to display the current settings for the specified
communications port. If you do not specify a communications port,
settins for all communications ports are displayed. The communications
port settings include baud rate, character echo, current output line
termination, current session mode, and time-out value.
COMM BAUD {1200|2400|4800|9600|19200}
COMM ECHO {ON|OFF}
COMM EOL {CR|LF|CRLF}
Use this option to change the setting for the port over which you are
communicating. If your security access level is Level 1, the setup
changes are not stored in non-volatile RAM.
Options are:
BAUD
Sets the current baud rate setting. Only the baud rates
shown above are valid.
ECHO
Enables or disables character echo on the terminal.
EOL {CR|LF|CRLF}
Sets the current End-Of-Line termination for an output line.
CR
Sets the line termination to carriage return (0xD).
LF
Sets the line termination to line feed (0xA).
CRLF
Sets the line termination to carriage return, followed by a
line feed.
Level 2
Same as Level 1 operation, with the following additions:
COMM {L|A|B} BAUD {1200|2400|4800|9600|19200}
COMM {L|A|B} ECHO {ON|OFF}
COMM {L|A|B} EOL {CR|LF|CRLF}
Level 3
Same as Level 2 operation, with the following additions:
COMM {L|A|B} MODE {ASCII|TL1}
COMM {L|A|B|TELNET|TL1} TIMEOUT {[5-43200]|NEVER}
Use this option to change the settings for the specified communications
port. The setup changes are stored in non-volatile RAM.