TL1 Command Interface
300
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
RTRV-PRMTR-SNMPV3-
NOTIFICATION:[tid]::ctag;
Valid aid code:
none
This command returns the current SNMPv3 notification type.
The format for each response message line is:
^^^"notification" <cr lf>
where:
notification
is {V2|V3|ALL} SNMPv2, SNMPv3, or
both types when event occurred
RTRV-PRMTR-SNMPV3-USER:[tid]::
ctag;
Valid aid code:
none
This command returns the current SNMPv3 user list. The
format for each response message line is:
^^^"username,level" <cr lf>
where:
username
= user identification string used by SNMPv3,
level
= access level assigned to that user. No
authentication or privacy key is displayed.
RTRV-PRMTR-SNMPV3-MANAGER:
[tid]::ctag;
Valid aid code:
none
This command returns the SNMPv3 Manager list. The
format for each response message line is:
^^^"ip,username" <cr lf>
where
ip
and
username
are the assigned SNMPv3 Manager
IP address and username.
RTRV-PRMTR-TL1FORMAT:[tid]::
ctag;
Valid aid code: None
This command returns the setting for the format of
autonomous reports.
The format of the response message is:
^^^"aid:mode" <cr lf>
where:
aid
= module or input port
mode
= format of the autonomous report [GR831|GR833]
RTRV-REF:[tid]::ctag;
Valid aid code: None
This command returns the current input reference port and
output clock source.
The format of the response message is:
^^^"port,clksrc" <cr lf>
where:
port
= input reference port designated by the aid
clksrc
= selected clock source [CLK-A|CLK-B|NA] for
outputs
Table B-5. TL1 Retrieve Commands (Continued)
Command
Description
Summary of Contents for SDU-2000