TL1 Command Interface
298
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
RTRV-PRMTR-OUTPUT:[tid]:[aid]
:ctag;
Valid aid code:
ALL
,
SxA[y[-z]]
Returns the output port setting when a port aid is specified.
The format for the response message is:
^^^"aid:mode,level,bypass,zs,crc,bit,pstate,len"
<cr lf>
where:
aid
= aid of the port
mode
= output signal mode [ESF|D4|CCS|CAS]
level
= [WARM|ACQ|LOCK] for the clock level where
outputs are turned on
bypass
= allow Clock C selection [ON|OFF]
zs
= zero suppression
crc
= error checking crc are [ON|OFF]
bit
= SSM bit [4 through 8] for E1 sync status messages
pstate
= port enabled state [ON|OFF]
len
= line length setting of [133|266|399|533|655] for
DS1 outputs
When the aid does not specify a port, the response is:
^^^"aid:mode,level,bypass,zs,crc,bit" <cr lf>
^^^"aid:pstate1,pstate2,…pstate20" <cr lf>
^^^"aid:len1,len2,len3,…,len20" <cr lf>
Line 1 contains:
aid
= module access identifier
mode
= outputs signal mode: [ESF|D4|CCS|CAS]
level
= clock level: [WARM|ACQ|LOCK] when outputs
are turned on
bypass
= allow Clock C selection: [ON|OFF]
zs
= zero suppression: [ON|OFF]
crc
= error checking: [ON|OFF]
bit
= SSM bit [4 through 8] for E1 sync status messages
Line 2 contains:
aid
= port access identifier
pstate#
= port enabled state [1|0] (1 = ON and 0 = OFF)
and
#
is the port number 1 through 20
Line 3 contains:
aid
= access identifier of the port
len#
= line length setting of [133|266|399|533|655] for all
20 DS1 output ports and
#
is the port number 1 through
20
Table B-5. TL1 Retrieve Commands (Continued)
Command
Description
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...