Alarm Messages
Table A-4. LRM Alarm Messages
Alarm
Description
Alarm
Number
Default
Alarm
Level
Status
Messages
Range
Description/
Corrective
Action
Side 1 Loss of
signal fault status
0
Minor
Ok
Fault
Minor
Verify signal is
connected. Can be
cleared by disabling
port.
Side 1 Alarm
indication signal
fault status
1
Report
Ok
Fault
Ignore
Report
Minor
Verify input signal is
good. Port can be
disabled.
Side 1 Loss of
frame signal fault
status
2
Report
Ok
Fault
Ignore
Report
Minor
Change frame type:
D4
ESF
Side 1 Bipolar
violation signal fault
status
3
Report
Ok
Fault
Ignore
Report
Minor
Verify port ZS is on.
Verify signal is good
Side 1 Slip signal
fault status
4
Report
Ok
Fault
Ignore
Report
Minor
Accumulated slip
value exceeded
threshold setting
Side 2 Loss of
signal fault status
5
Report
Ok
Fault
Ignore
Report
Verify signal on side
2 is connected. Can
be cleared by
disabling port.
Reference PLL
fault
10
Minor
Ok
Fault
Minor
Verify clock reference
source is good.
Reference PLL is
unlocked
CTA Fuse
11
Minor
Ok
Fault
Ignore
Report
Minor
Verify CTA fuse is
good
CTA
12
Minor
OK
Fault
Ignore
Report
Minor
CTA present/not
present
Mismatch Dual/Quad
Summary of Contents for SDU-2000
Page 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Page 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...