RS 2200/3200 Series
SYMBOL MOBILE
GATEWAY
Product Guide
Page 1: ...RS 2200 3200 Series SYMBOL MOBILE GATEWAY Product Guide...
Page 2: ...ass A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat ri...
Page 3: ...SMG supports a DOS operating environment using industry standard protocols It is available with either an 8088 or 80386SX processor Power Requirements 12 to 24 volts DC Peripherals Supported The SMG...
Page 4: ...shown as a nine pin RS 232 connector Optionally it may be configured as an RS 422 port utilizing an RJ45 connector COM 4 WLAN Keyboard GPS WWAN 12 24 VDC COM 1 COM 3 COM 2 One Type III and one Type I...
Page 5: ...wireless local area communications between Symbol portable data terminals and the SMG 12 24VDC 4 pin power connector with chassis ground You may also have up to two of the following options COM3 Addi...
Page 6: ...fuse 1 amp slo blo Littlefuse p n 313 001008 4 Four crimp pins AMP p n 66103 4 5 One circular connector housing AMP p n 206429 1 6 One cable clamp AMP p n 206062 1 7 Two CAUTION labels Europort p n 0...
Page 7: ...G with appropriate nuts and bolts Self locking nuts or lock washers must be used 3 Construct the power cable CrimpAMP pins onto wire ends usingAMP toolA9999 or equivalent Slide cable clamp over wire a...
Page 8: ...a fuseholder with a 1 amp fuse in line with the accessory power source Note Locate the fuse as close as possible to the accessory power source The accessory bus is the switched power source con trolle...
Page 9: ...as an RS 422 compatible port a RJ45 connector is provided with pinouts as listed in Table 3 below Table 2 COM 1 COM2 COM3 COM4 Port Pin outs Pin No Function 3 Transmit Data 2 Receive Data 7 Request to...
Page 10: ...to the vehicle accessory bus i e vehicle power is turned on the SMG powers up and goes through the normal boot cycle If power is ap plied to the accessory bus prior to the SMG being deactivated the h...
Page 11: ...quence for the SMG is initiated by the application setting port 37AH bit 3 to logic 1 This starts the hardware timer which shuts down the SMG in 3 to 5 minutes Note The only way to halt and reset the...
Page 12: ...mful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference...
Page 13: ...nterference that may cause undesired operation of the device Ce dispositif satisfait aux exigences d Industrie Canada prescrites dans le document CNR 210 Son utilisation est autoris e seulement aux co...
Page 14: ...d that the product remains unmodified and is operated under normal and proper conditions This warranty is limited to repair or replacement at Symbol s option with reasonable promptness after being ret...