7-14
MS-804FZY and MS-904HS Integration Guide
Triggering Modes
Parameter # 8Ah
•
Level
- A trigger pull activates the laser and decode processing. The laser remains
on and decode processing continues until a trigger release, a valid decode, or the
Laser On Time-out is reached.
•
Pulse
- A trigger pull activates the laser and decode processing. The laser remains
on and decode processing continues until a valid decode or the Laser On Time-out
is reached.
•
Continuous
- The laser is always on and decoding.
•
Blinking
- This trigger mode is used for triggerless ScanStand operation. Scanning
range is reduced in this mode. This mode cannot be used with scanners that
support an aim mode.
•
Host
- A host command issues the triggering signal. The scanner interprets an
actual trigger pull as a Level triggering option.
*Level
(00h)
Pulse
(02h)
Continuous
(04h)
Host
(08h)
Blinking
(07h)