![Symbol MiniScan MS-120X Integration Manual Download Page 56](http://html1.mh-extra.com/html/symbol/miniscan-ms-120x/miniscan-ms-120x_integration-manual_1419146056.webp)
3-8
MS-120X and MS-220X Integration Guide
Usable Scan Length
The decode zone is a function of various symbol characteristics including density, print
contrast, wide-to-narrow ratio, and edge acuity. Consider width of decode zone at any given
distance when designing a system.
Calculating The Usable Scan Length Method
on page 2-14 describes how to calculate the
usable scan length. The scan angle is provided in
Table 3-3. MS-1207WA Decode Distances
Symbol Density/
Symbol p/n /
Bar Code Type/
W-N Ratio
Bar Code
Content/
Contrast
1
Typical Working
Ranges
Guaranteed Working
Ranges
Near
Far
Near
Far
5 mil
64-17453-01
Code 39; 2.5:1
ABCDEFGH
80% MRD
1.0 in.
2.54 cm
4.0 in.
10.16 cm
1.2 in.
3.05 cm
3.0 in.
7.62 cm
7.5 mil
64-17452-01
Code 39; 2.5:1
ABCDEF
80% MRD
0.6 in.
1.52 cm
7.2 in.
18.29 cm
0.9 in.
2.29 cm
6.0 in.
15.24 cm
13 mil
64-05303-01
100% UPC
1234567890
80% MRD
0.6 in.
1.52 cm
11.0 in.
27.94 cm
0.9 in.
2.29 cm
9.0 in.
22.86 cm
20 mil
60-01429-01
Code 39; 2.2:1
123
80% MRD
Note 2
15.0 in.
38.10 cm
Note 2
13.0 in.
33.02 cm
40 mil
64-17457-01
Code 39; 2.2:1
AB
80% MRD
Note 2
19.0 in.
48.26 cm
Note 2
17.0 in.
43.18 cm
55 mil
64-17458-01
Code 39; 2.2:1
CD
80% MRD
Note 2
24.0 in.
60.96 cm
Note 2
22.0 in.
55.88 cm
1. CONTRAST measured as Mean Reflective Difference (MRD) at 670 nm.
2. Near ranges on lower densities (not specified) largely depend on the width of the bar code
and the scan angle.
3. Working range specifications at ambient temperature 23 °C.
Summary of Contents for MiniScan MS-120X
Page 1: ...MiniScan MS 120X and MS 220X Integration Guide ...
Page 2: ......
Page 3: ...MiniScan MS 120X and MS 220X Integration Guide 72 63538 02 Revision A November 2003 ...
Page 14: ...xii MS 120X and MS 220X Integration Guide ...
Page 58: ...3 10 MS 120X and MS 220X Integration Guide ...
Page 90: ...6 10 MS 120X and MS 220X Integration Guide ...
Page 94: ...7 4 MS 120X and MS 220X Integration Guide ...
Page 241: ...9 145 Parameter Menus Numeric Bar Codes continued 4 5 6 7 ...
Page 251: ...10 9 RS 232 Interface Baud Rate continued Baud Rate 9600 Baud Rate 19 200 Baud Rate 38 400 ...
Page 266: ...10 24 MS 120X and MS 220X Integration Guide ...
Page 280: ...11 14 MS 120X and MS 220X Integration Guide ...
Page 362: ...13 80 MS 120X and MS 220X Integration Guide Alphanumeric Keyboard Space Dash ...
Page 363: ...13 81 Advanced Data Formatting MS 1207 MS 2207 Only Alphanumeric Keyboard continued ...
Page 364: ...13 82 MS 120X and MS 220X Integration Guide Alphanumeric Keyboard continued _ Underscore ...
Page 372: ...13 90 MS 120X and MS 220X Integration Guide ...
Page 376: ...15 2 MS 120X and MS 220X Integration Guide ...
Page 394: ...A 18 MS 120X and MS 220X Integration Guide ...
Page 406: ...Index 6 MS 120X and MS 220X Integration Guide ...
Page 408: ......
Page 409: ......