Programming
5-113
Set Lengths for Interleaved 2 of 5
Lengths for I 2 of 5 may be set for any length, one or two
discrete lengths, or lengths within a specific range. The
length of a code refers to the number of characters (i.e.,
human readable characters) the code contains, and
includes check digits. Scan the appropriate bar code to
select one of the following options.
One Discrete Length
This option allows you to decode only those codes
containing a selected length. For example, if you select
I 2 of 5 One Discrete Length
, then scan
1
,
4
, the only I
2 of 5 symbols decoded are those containing 14
characters. Numeric bar codes begin on page
you make an error or wish to change your selection,
scan
Two Discrete Lengths
This option allows you to decode only those codes
containing two selected lengths. For example, if you
select
I 2 of 5 Two Discrete Lengths
, then scan
0
,
2
,
1
,
I 2 of 5 - ONE DISCRETE LENGTH
Summary of Contents for LS 6000i
Page 1: ...Product Reference Guide LS 6000i Series...
Page 2: ...LS 6000i Series Product Reference Guide 72 51596 01 Revision A July 2001...
Page 8: ...vii Contents Modifier Characters A 5 ASCII Character Set A 9 Tell Us What You Think...
Page 9: ...viii LS 6000i Series Product Reference Guide...
Page 23: ...LS 6000i Series Product Reference Guide 1 4...
Page 35: ...LS 6000i Series Product Reference Guide 3 8...
Page 53: ...LS 6000i Series Product Reference Guide 5 12 Host Type Cont d Port 9B Port 17 9E...
Page 58: ...Programming 5 17 RS 232C Host Types Cont d NIXDORF RS 232C Mode A NIXDORF RS 232C Mode B...
Page 59: ...LS 6000i Series Product Reference Guide 5 18 RS 232C Host Types Cont d FUJITSU RS 232C...
Page 61: ...LS 6000i Series Product Reference Guide 5 20 Baud Rate Cont d BAUD RATE 600 BAUD RATE 1200...
Page 62: ...Programming 5 21 Baud Rate Cont d BAUD RATE 2400 BAUD RATE 4800...
Page 63: ...LS 6000i Series Product Reference Guide 5 22 Baud Rate Cont d BAUD RATE 9600 BAUD RATE 19 200...
Page 88: ...Programming 5 47 German Windows German MacOS French Canadian Windows French Canadian MacOS...
Page 90: ...Programming 5 49 Swedish MacOS UK English Windows Swedish Windows...
Page 99: ...LS 6000i Series Product Reference Guide 5 58 Beeper Volume Cont d MEDIUM VOLUME HIGH VOLUME...
Page 106: ...Programming 5 65 Rest Mode Timeout Cont d 60 MINUTES 90 MINUTES...
Page 111: ...LS 6000i Series Product Reference Guide 5 70 LINEAR SECURITY LEVEL 4...
Page 158: ...Programming 5 117 I 2 of 5 Check Digit Verification Cont d USS CHECK DIGIT OPCC CHECK DIGIT...
Page 167: ...LS 6000i Series Product Reference Guide 5 126 RSS Codes RSS 14 Enable RSS 14 Disable RSS 14...
Page 168: ...Programming 5 127 RSS Limited Enable RSS Limited Disable RSS Limited...
Page 172: ...Programming 5 131 Transmit Code ID Character Cont d AIM CODE ID CHARACTER NONE...
Page 176: ...Programming 5 135 Scan Data Transmission Format Cont d DATA AS IS DATA SUFFIX...
Page 178: ...Programming 5 137 Scan Data Transmission Format Cont d ENTER DATA FORMAT CANCEL...
Page 180: ...Programming 5 139 Numeric Bar Codes Cont d 2 3...
Page 181: ...LS 6000i Series Product Reference Guide 5 140 Numeric Bar Codes Cont d 4 5...
Page 182: ...Programming 5 141 Numeric Bar Codes Cont d 6 7...
Page 183: ...LS 6000i Series Product Reference Guide 5 142 Numeric Bar Codes Cont d 8 9...
Page 185: ...LS 6000i Series Product Reference Guide 5 144...