Symbio Microscope 

 

 

L1500 Series 

 

Biological Upright Compound Microscopes 

 

 

Operating Manual 

 

 

Summary of Contents for L1500 Series

Page 1: ... Coopers Place Combe Lane Wormley Surrey GU8 5SZ Tel 44 0 1428 685762 Fax 44 0 1428 685702 www symbio co uk info symbio co uk 1 Symbio Microscope L1500 Series Biological Upright Compound Microscopes Operating Manual ...

Page 2: ... are especially popular as teaching tools in universities and colleges SPECIFICATIONS 1 Eyepieces Type Magnification Focus mm Field mm Remark Wide field eyepiece 10X 25 φ18 Plan eyepiece 16X 15 6 φ11 Optional 2 Objectives Type Magnification N A W D mm Achromatic or Semi Plan Achromatic Achromatic Semi Plan 4X 0 1 37 4 23 1 10X 0 25 6 6 4 1 40X 0 65 0 64 0 6 100X oil 1 25 0 19 0 38 3 Total Magnific...

Page 3: ...Symbio Unit 8 Coopers Place Combe Lane Wormley Surrey GU8 5SZ Tel 44 0 1428 685762 Fax 44 0 1428 685702 www symbio co uk info symbio co uk 3 COMPONENTS ...

Page 4: ...Symbio Unit 8 Coopers Place Combe Lane Wormley Surrey GU8 5SZ Tel 44 0 1428 685762 Fax 44 0 1428 685702 www symbio co uk info symbio co uk 4 Fig 1 Fig 2 ...

Page 5: ...djust interpupillary distance and diopter whilst observing through the binocular eyepieces 4 Adjust the up down position of the condenser light control and aperture diaphragm in order to obtain the optimal illumination effect Select the 4X or 10X objective bring down the condenser using the condenser s rack and pinion knob to obtain symmetrical light 5 When selecting other objectives turn the nose...

Page 6: ...ield of view can be composed one Fig 4 Put the specimen on the stage Turn the 40X objective to working position Firstly observe at right column with right eye adjust coarse fine focusing knob to image clearly Secondly observe at left column with left eye adjust the diopter control to image clearly Fig 5 Fig 5 The instrument used coaxial coarse fine focusing mechanism The adjustable tensional knob ...

Page 7: ...n the filter seat Fig 8 Turn on the power switch adjust the light control until image can be observed comfortably Fig 8 Note Do not let the light control stay at the highest intensity position or it will reduce the life span of the lamp 6 Powerswitchandadjustablebrightness Fig 8 Switch on the power put the specimen on the stage then turn the 10X objective into the working position observe with 10X...

Page 8: ... the screw The specification of fuse φ5 0 5A MAINTENANCE 1 Cleaning the optics Clean the optics using lens tissue or soft fabric immersed in methanol Clean off excess immersion oil from the 100X objective after every use 2 Cleaning the painted parts The dust on the painted parts can be removed by a lint free cloth or blower brush for the grease spots the gauze immersed slightly with methanol is re...

Page 9: ...ne Wormley Surrey GU8 5SZ Tel 44 0 1428 685762 Fax 44 0 1428 685702 www symbio co uk info symbio co uk 9 SYMBIO MICROSCOPES SLIDER PHASE CONTRAST KITS USER MANUAL Example Phase Objectives Slider Type Phase contrast condensers with inserts ...

Page 10: ...contrast plate inserted which must have the same magnification indicated on it as the objective currently selected See below example Operating Procedure 1 Select a phase contrast objective insert the corresponding phase contrast plate in position adjust the condenser knob to move the condenser into the optimum position 2 Place a specimen slide on the stage and focus onto the specimen 3 Remove one ...