Summary of Contents for 10000-12000Btu/h

Page 1: ...Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER ...

Page 2: ...ioner is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replaced replacement work should be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only CAUTI...

Page 3: ... fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric shock It may cause fire and electric shock It may cause electric shock or fire If the power cord is damaged it must be replaced by the manufac turer or an authorised service center or a si...

Page 4: ...es food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service techn...

Page 5: ...cannot be repaired it must be replaced with a cord from the Product Manufacturer Do not under any circumstances cut remove or bypass the grounding prong Power supply cord with 3 prong grounding plug and current detection device Operation of Current Device Applicable to the unit adopts current detection device only The power supply cord contains a current device that senses damage to the power cord...

Page 6: ...el and remote as shown below and all its functions then follow the symbol for the functions you desire The unit can be controlled by the unit control alone or with the remote Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation ELECTRONIC CONTROL OPERATING INSTRUCTIONS ADJUSTS TEMPERATURE OR TIME ADJUSTS TEMPERATURE OR TIME DISPLAYS TEMPER...

Page 7: ...on until the desired temperature is seen on the display This temperature will be automatically maintained anywhere between 62 F 17 C and 86 F 30 C If you want the display to read the actual room temperature see To Operate on Fan Only section NOTE TO ADJUST FAN SPEEDS Auto Cool Dry Fan Low Auto Med High Clean Air Fan Mode Follow Me Energy Saver On Off Press to select appropriate fan speed DO THIS U...

Page 8: ...ressor shuts off The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature at which time the compressor turns back on and Cooling Starts NOTE Temp Temp Timer Timer On Off Sleep Check Filter Timer Auto Cool Dry Fan Low Auto Med High Clean Air SLEEP FEATURE Press Sleep button DO THIS In this mode the selected temperature will increase by O O ...

Page 9: ...ON is displayed Press or hold the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start The selected time will register in 5 seconds and the system will automatically revert back to display the previous temperature setting or room temperature when the unit is on when the un...

Page 10: ...ULD KNOW Now that you have mastered the operating procedure here are more features in your control that you should become familiar with The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during this time The control is capable of display...

Page 11: ...t must be outdoors not inside a building or garage NOTE Save Carton and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use 3 4 or 1 Screws 7 2 Lock Frame 2 Sash Lock 1 Mounting Hardware TOOLS NEEDED Phillips Screw Driver Drill If pilot holes are needed CAUTION When handling unit be careful to avoid cuts from sharp metal ed...

Page 12: ...ft and right wings necessary for proper condensed water utilization and drainage If you are not using the Side Panels for any reason this pitch to the rear must be maintained 1 Fig 1 A Hold the Accordion Panel in one hand and gently pull back the center to free the open end See Fig 1 Fig 2A Fig 2B B Slide the free end I section of the panel into the cabinet as shown in Fig 2A 2B 3 Slide the panel ...

Page 13: ...rive 3 4 19mm or 1 locking screws through the frame lock and into the sill Fig 8 NOTE To prevent window sill from splitting drill 1 8 3mm pilot holes before driving screws 2 13mm 4 Fig 7 Fig 8 12 Fig 4 C Once the panel has been installed on the side of the cabinet make sure it sits securely inside the frame channel by making slight adjustments Slide the top and bottom ends of the frame into the to...

Page 14: ...ted shut Accumulated Rain Water or Condensation must be allowed to drain out Storm window frame or other obstruction 11 2 MIN 38 mm Sash Board thickness as required for proper pitch to rear along entire sill Fasten with nails or screws Fig 13 Removing AC From Window 13 Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety lock Remove screws installed throug...

Page 15: ...nstead of washing you may vacuum the filter clean Note Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwa...

Page 16: ...F Turn Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 18 C 64 F To defrost the coil set FAN ONLY mode O O Air conditioner cooling but room is too warm NO ice forming on cooling coil behind decorative front Temperature is set too High set temperature to a Lower setting Air direc...

Page 17: ...s is normal during excessively humid days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obstructed Remove obstruction Room too cold Set temperature too low Increase set temperature 16 ...

Page 18: ...2020001A6027 SYLVANIA is a registered trademark of OSRAM SYLVANIA Inc used under license ...