background image

3

 

System layout

SYSTEM LAYOUT

85

2003

1172

1148

46,5

46,5

Collector

outlet

Collector

return

Collector

probe socket

Glass 3,2 mm.

Connection

ring nut, 1"

Connector Ø 22 mm.

Ventilation holes

Direction of flow of

heat transfer liquid

Identification

IDENTIFICATION

CODICE :          

20091463

TIPO : CP25TOS

S/N : 

COLLETTORE SOLARE PIANO

DIMENSIONI: 1148X2003X85 mm

SUPERFICIE LORDA: 2,30 m

2                               

                             

TEMPERATURA DI STAGNAZIONE: 200°C 

SUPERFICIE DI APERTURA: 2,16 m

2           

                             

CONTENUTO LIQUIDO: 1,6 l

SUPERFICIE ASSORBITORE: 2,15 m

2  

                             

PESO A VUOTO: 41 kg

LIQUIDO TERMOVETTORE:

 

ACQUA+GLICOLE PROPILENICO

MAX CONCENTRAZIONE GLICOLE: 50%

MAX PRESSIONE ESERCIZIO: 10 bar

FABBRICATO IN ITALIA

20092485_E4

EN 12975

13000000

BAR CODE 128B

Anno di produzione

SERIALE PROGRESSIVO

da Riello S.p.A.

Certif. 011-7S2505 F

Code

Year of production

Serial Number

Description

Flat plate 

solar collector

Dimensions

Gross area

Aperture area

Absorber area

Empty weight

Maximum operating pressure

Stagnation temperature

Liquid content

Max glycol concentration

Heat transfer fluid:

water+propylene glycol

Serial number plate

by Riello S.p.A.

Made in Italy

Data plate

Data label

To be applied to the back of

the solar collector on installation

Codice . . . . . . . . 
Modello . . . . . . . 
Matricola . . . . . . 

Codice . . . . . . . . . . . . . . . . . . . . . 
Tipo . . . . . . . . . . . . . . . . . . . . . . . 
Dimensioni. . . . . . . . . . . . . . . . . . 
Superficie lorda . . . . . . . . . . . . . . 
Superficie di apertura . . . . . . . . . 
Superficie assorbitore . . . . . . . . . 
Peso a vuoto . . . . . . . . . . . . . . . . 
Massima pressione di esercizio . 
Temperatura di stagnazione . . . . 
Contenuto liquido . . . . . . . . . . . . 
Massima concentrazione glicole . 

COLLETTORE SOLARE (neutro)

FABBRICATO IN ITALIA da Riello S.p.A.

Liquido termovettore . . . . . . . . . . 

COLLS1_IT

Serial N°

Model

Code

 

b

If these plates or any other means of clearly identifying the product are defaced, removed or lost, proper installation 

and servicing may be rendered difficult.

Summary of Contents for CFO-25S

Page 1: ...SOLAR COLLECTOR CFO 25S INSTALLATION MANUAL ...

Page 2: ... persons or animals caused by improper installation adjustment maintenance or use Range RANGE MODEL CODE CFO 25S 20099917 CFO 25S pack of 5 20099918 Contents CONTENTS The following symbols are used in this manual b b CAUTION Identifies actions that require caution and adequate preparation a a STOP Identifies actions that you MUST NOT do This manual Code Rev comprises pages System layout 3 Identifi...

Page 3: ...ertif 011 7S2505 F Code Year of production Serial Number Description Flat plate solar collector Dimensions Gross area Aperture area Absorber area Empty weight Maximum operating pressure Stagnation temperature Liquid content Max glycol concentration Heat transfer fluid water propylene glycol Serial number plate by Riello S p A Made in Italy Data plate Data label To be applied to the back of the sol...

Page 4: ...U M IAM 50 0 93 Collector efficiency ηcol 59 2 Tested according to EN 12975 referred to a 33 3 water glycol mix flow rate of 160 l h and irradiation G 800W m2 Tm Coll _inlet _temp Coll _outlet_temp 2 T m Tm T_ambient G Calculated with a temperature difference of 40K be tween the solar collector and the surrounding air and with total solar radiation of 1000 W m2 referred to the exposed area Efficie...

Page 5: ...e line see figure Lines of solar collectors can be connected either in series provided each line contains no more than 6 collectors or in parallel The complete circuit must always be hydraulically balanced See the following sample layouts Only the proper fittings must be used to connect one collector to another These are provided separately and include insulated connector pipes Do not fix the ends...

Page 6: ...4 4 9 8 11 10 13 14 6 12 Water control system 7 5 3 19 1 1 R M 2 17 15 16 18 Solar Regolator b b If copper pipes are used joints must be hot brazed b b We recommend the use of stainless steel pipes spe cially made for solar collectors for the outlet return and probe pipes The probe cable should be of the shielded type b b Do not use plastic or multistrate pipes Operating temperature can exceed 180...

Page 7: ... service im mediately A B 1 1 Handling HANDLING Remove the PVC wrapping to free the solar collector from the pallet Apply the data label provided in the document enve lope to the back of the solar collector Once you have removed the outer packaging proceed as follows to unpack and handle the solar collector Tilt the solar collector slightly and grip it at the four points shown A to lift it Use a h...

Page 8: ...ater circuit must be insulated in conform ity to relevant standards Lagging and insulation must be protected against damage by the weather and birds and animals Angle of collectors General Solar collectors are designed to be installed at angles of between 15 minimum and 75 maximum Make sure that the bleed and vent valves of the collectors remain open while the collectors are being installed Take c...

Page 9: ...solar circuit at ambient temper ature with the collectors shielded from the sun s rays 1 Open the non return valve A 2 Open the air vent at the highest point in the system see figure alongside and keep it open throughout the filling operation 3 Open the vent valve 7 4 Pump the heat transfer fluid around the circuit with an external filling pump until all air bubbles have been eliminated Close the ...

Page 10: ...ery two years MAINTENANCE Collector circuit Cold circuit pressure ____bar see table above Collector circuit seal test Safety valve check Anti freeze checked to ___ C pH of heat transfer fluid ____ Collector circuit bled Flow rate of 30 l h per m2 checked Non return valve functioning Solar collectors Visual check of collectors Collectors cleaned if necessary Visual check of collector fixing points ...

Page 11: ...11 ...

Page 12: ... 02 16 www sylber it The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefore liable to modification without notice ...

Reviews: