Sygonix 2380476 Operating Instructions Download Page 1

Connections and controls

1  Opening for wall mounting
2  LED
3  RFID/fingerprint sensor with LED ring

Connecting cable:

Colour

Inscription

Function

Red

9 - 24 V/DC

Operating voltage 9 - 24 V/DC

Black

GND

GND/ground

Yellow

OPEN

Door opener button

Green

NC

NC (normally closed) contact of relay

Brown

COM

COM (centre contact) contact of relay

White

NO

NO (normally open) contact of relay

Installation and connection

Use suitable screws and, if necessary, dowels 

to mount the mounting plate with the module 

on the wall (see figure on the right) depending 

on the type of wall.
The included mounting frame can be pre-in-

stalled depending on the substrate and instal-

lation position, and the access system should 

then be screwed tight. Suitable screws and, if 

necessary, dowels should be used depending 

on the substrate.
A hole for the connecting cable must be drilled 

before fastening.

  Ensure  that  no  cables  or  wires 

are damaged when drilling holes 

or tightening screws.

Wiring should be carried out according to the following examples. 

  Ensure that there is suitable insulation (e.g. heat shrink tubing).

A protective diode is included for connecting a door opener. It protects the electronics from damage caused 

by voltage surges. Ensure the correct polarity, as shown in the following connection examples (when con-

nected, the ring on the protective diode must face the positive pole/+).

 Attention!

 

Never switch the mains voltage via the potential-free changeover contact! There is a risk of fatal 

electric shock! Observe the permissible contact rating; see “Technical data” chapter.

  Use suitable cables with different colours. Note the colours and store this information together 

with these instructions. When connecting the cables, pay attention to the correct polarity (plus/+ 

and minus/-). 

Connection to conventional voltage/power supply:
When a conventional power supply unit should be 

used, observe the wiring diagram on the right.
A)  “Fail  Secure”  door  opener:  Releases  the  lock-

ing latch only when its operating voltage is applied 

(common design for front doors). 
B)  “Fail-safe”  door  opener:  releases  the  locking 

latch  only  when  the  operating  voltage  is  missing 

(uncommon  design,  e.g.  used  for  escape  route 

doors, which can be opened in the event of a power 

outage). 
1  Access system
2  Door opener button
3  Power adapter
4  “Fail-Secure” door openers
5  “Fail-Safe” door openers
The  included  diode  must  be  connected  correctly 

near the door opener to protect the access system 

from voltage surges. 
Connecting to alarm system
Observe  the  operating  instructions  for  the  alarm 

system  used.  The  access  system  relay  switches 

when  a  valid  transponder  is  recognised  or  when 

a stored finger is placed on the sensor. The alarm 

system can thus be enabled or disabled.

Operation

Switch on the operating voltage after installation and connection. The access system LED lights up red. This 

indicates that the access system is in standby mode. You can now start programming, see next chapter.

 Operating instructions

RFID/fingerprint access system

Item no. 2380476

Intended use

This product is designed to prevent unauthorised access to doors (e.g. in an office) and to activate/disable 

alarm systems. Control can be exercised via suitable transponders or fingerprints.
Holding a paired user transponder in front of the reading surface or placing a stored finger on the fingerprint 

sensor activates a potential-free relay changeover contact (see contact rating under “Technical data”). This 

can be used, for example, to control a door opener or an alarm system.
The product is intended for vertical installation on a wall and is suitable for indoor and outdoor use (IP 66).
For safety and approval purposes, do not rebuild and/or modify this product. Using the product for purposes 

other than those described above may damage the product. In addition, improper use can cause hazards 

such as a short circuit, fire or electric shock. Read the operating instructions carefully and store them in a 

safe place. Only make this product available to third parties together with its operating instructions.
This product complies with statutory, national and European regulations. All company and product names 

contained herein are trademarks of their respective owners. All rights reserved.

Delivery content

•  RFID/fingerprint module
•  Fasteners (2x special screws with matching L-key, 4x screw head stickers, mounting frame with 2x screws 

and 2x dowels)

•  Master transponder
•  1N4004 diode (for relay changeover contact)
•  Operating instructions

Up-to-date operating instructions           

Download the latest operating instructions at www.conrad.com/downloads or scan the QR code shown. 

Follow the instructions on the website.

Description of symbols

  The symbol with an exclamation mark in a triangle is used to highlight important information in 

these operating instructions. Always read this information carefully.

  The arrow symbol indicates special information and tips on how to use the product.

Safety information

Read the operating instructions carefully and observe in particular the safety instruc-

tions. If you do not follow the safety information and information on proper handling in 

these operating instructions, we will assume no liability for any resulting personal injury 

or damage to property. Such cases will invalidate the warranty/guarantee.
•  This product is not a toy. Keep it out of the reach of children and pets.
•  Protect  the  product  from  extreme  temperatures,  impacts,  flammable  gases,  vapours  and 

solvents. 

•  Handle the product carefully. Jolts, impacts or a fall even from a low height may damage the 

product. Do not place the product under any mechanical stress.

•  Do not mount or connect the product when it is connected to a power supply. 
•  Never exceed the contact rating for the potential-free changeover contact specified in chapter 

“Technical data”. Never switch the mains voltage, as this can cause life-threatening electric 

shock!

•  Always observe the safety and operating instructions of any other devices which are con-

nected to the product (e.g. door openers and alarm systems).

•  If it is no longer possible to operate the product safely, stop using it and prevent unauthorised 

use. Safe operation of the appliance can no longer be guaranteed if it shows visible signs of 

damage, malfunctions, has been exposed to unfavourable storage conditions or significant 

transport loads.

•  For installations in industrial facilities, follow the accident prevention regulations for electri-

cal systems and equipment issued by the national safety organisation or the corresponding 

national authority.

•  Do not leave packaging material lying around carelessly. It may become a dangerous toy 

for children!

•  Maintenance, modifications and repairs must be carried out by a technician or a specialist 

repair centre.

•  If you are not sure how to operate the product correctly, or if you have any questions that are 

not answered in these operating instructions, contact us or another specialist.