Page 2: ... Products 3 3 0 Connections 3 4 0 Supply Input 4 5 0 Motor 4 6 0 Safe Torque Off 5 7 0 Relays 5 8 0 Motor Temperature Sensor 5 9 0 Analog Input 6 10 0 Digital Inputs 6 11 0 Micro SD Card 6 12 0 SycoDrive Operating Software 7 12 1 Configuration and Commissioning 7 12 1 1 Operation with SycoDrive operating software 8 12 1 2 Operation with digital analog inputs 9 12 2 Diagnosis 10 13 0 Switch on sequ...
Page 3: ...alid for following high frequency inverters HF Inverter e syDrive 4624 Material no 2 002 1053 HF Inverter e syDrive 4625 Material no 2 002 1054 HF Inverter e syDrive 4626 Material no 2 002 1055 3 0 Connections 1 Supply input max 70 V DC 49 V AC 1 3 2 Motor U V W 10 13 3 Safe Torque Off 20 27 4 Relays 30 35 5 Digital inputs PLC 50 59 6 CAN interface 60 63 7 Motor temperature sensor 40 41 8 Frequenc...
Page 4: ...4626 the following must be observed DANGER AC voltage max 49 V AC DC voltage max 70 V DC 5 0 Motor Pin Name I O Meaning 10 U O Motor phase U 11 V O Motor phase V 12 W O Motor phase W 13 PE Protective conductor Before connecting or disconnecting the motor make sure that the frequency inverter is disconnected from the power supply When connecting the motor to U V W and PE ensure that the cable shiel...
Page 5: ... 22 are connected to 24 V 24 26 and STO1 21 and STO2 23 are connected to GND 25 27 If the safety function is not required bridge the necessary pins 7 0 Relays Pin Name I O Meaning 30 NO O Normally open Relay 1 Motor runs 31 COM Common Relay 32 NC O Normally closed Relay 1 Motor runs 33 NO O Normally open Relay 2 Failure 34 COM Common Relay 35 NC O Normally closed Relay 2 Failure The functions of t...
Page 6: ...figured with the SycoDrive operating software as needed An internal 24 V DC auxiliary voltage max 0 5 mA is available from the frequency inverter 11 0 Micro SD Card Error log With a micro SD card it is possible to read out the frequency inverter s error log with associated timestamp from the time that the micro SD card was connected Loading the parameters Parameters can be saved to a micro SD card...
Page 7: ... supply can be used to connect the PC to the frequency inverter You will also need the SycoDrive operating software which can be downloaded free of charge from the website www sycotec eu Connection Install the SycoDrive operating software on your PC Open SycoDrive Switch on the frequency inverter Connect the PC to the frequency inverter the frequency inverter will detect the COM port automatically...
Page 8: ... Operation with SycoDrive operating software For operation using the SycoDrive operating software please configure the following parameters on the STARTPAGE as shown Input for Start SycoDrive Input for rated frequency SycoDrive Then confirm the parameters with the Save on inverter button in order to transfer them to the inverter ...
Page 9: ...s shown Input for start Digital inputs Input for rated frequency Analog input Then select the following in the INPUTS OUTPUTS menu DIN 1 Start Stop AIN U 0 10 V The parameters Maximum voltage and Maximum frequency allow the analog input to be scaled Then confirm the parameters with the Save on inverter button in order to transfer them to the inverter ...
Page 10: ... safety reasons it is not possible to switch on the inverter and simultaneously indicate the start command and the setpoint A deliberate command must be executed to start the motor Note the following switch on sequence 1 Switch on the inverter 2 Wait during the initialization process until the inverter is ready for operation 3 Set the setpoint 4 Give the start command ATTENTION Do not switch off t...
Page 11: ...er handling cleaning or maintenance non compliance with the maintenance operating or connecting instructions corrosion impurities in the air supply or chemical or electrical influences which are unusual or not admissible in accordance with SycoTec s standards The warranty claims shall become null and void if defects or their consequences can be attributed to interventions in or modifications to th...