TWO-PIECE TOILET
INSTALLATION INSTRUCTIONS
1. Read the complete instruction manual before beginning installation.
2. Confirm that your model will fit in intended location and plumbing fixtures are located where
legally required before beginning installation.
3. Not all drawings on this manual are drawn to scale. Please refer to the model chart.
4. Two people are recommended to install and move this product.
5. Product is FRAGILE! To avoid breakage and possible injury handle with care and avoid over
tightening bolts and nuts.
6. Fill valve has been factory-tightened to design specifications. If re-tightening required, use a
wrench a tighten one turn past finger tight.
7. Make sure the supply pressure is a minimum of 35 psi (2.5kg/cm³), the toilet will not function
properly without minimum water pressure.
— 4 —
The step-by-step guidelines in the installation instructions are a general reference for installing a Swiss Madison Two-Piece Toilet.
Should there be any discrepancies, Swiss Madison cannot be held liable.
It is recommended to install all Swiss Madison products by hiring a licensed professional
1. Remove Old Toilet
Close toilet supply valve and flush tank completely, use towel or sponge to remove excess water.
Disconnect and remove supply line, if you are replacing the valve shut off the main water supply first.
Remove old mounting hardware, remove toilet and plug waste opening to prevent escaping gas.
Remove closet bolts from flange and clean away old wax, putty, etc. from base area.
2. Identify Outlet Installation Type
For wall-outlet installation, place the pipe
fittings as shown above.
For floor-outlet installation, place the pipe
fittings as shown above.