ELECTRICS
67
ELECTRICS
67
The following table shows details of the fuse(s)
located at the Road Light fuse box.
Fuse
Rating
Fuse Colour
Description
1
20 Amps
Yellow
Fridge Supply
2
5 Amps
Tan
Left Hand Tail Lights
3
5 Amps
Tan
Right Hand Indicators
4
5 Amps
Tan
Fog Lights
5
-
-
Not fitted
6
20 Amps
Yellow
Car Battery Supply
7
5 Amps
Tan
Right Hand Tail Lights
8
5 Amps
Tan
Left Hand Indicators
9
7.5 Amps
Brown
Stop Lights
10
5 Amps
Tan
Reverse Lights
3.6 Solar Charge Management
The EC601/602 PSU incorporates a built-in
solar charge management feature, which will
monitor the input from a separate solar panel
and regulator. The Solar Active symbol will be
displayed on the control panel when there is
an amount of energy available to charge the
battery. The voltage and current produced
from the regulator can be viewed on the multi-
function display by selecting the Solar Power
menu item.
3.7 Water Pump Operation
The EC620 control panel pump button
operates the internal water pump drawing
water from an internal tank if fitted, or an
external container when no internal tank is
fitted.
The system incorporates an automatic tank fill
feature. When turned on this will automatically
fill the onboard water tank from the external
container and will switch off automatically
when full. To enable tank fill, select ‘Tank-fill on’
on the control panel. To ensure the external
pump is not damaged if the external tank
runs dry, the pump runs for a maximum of 7
minutes.
The water tanks (fresh & waste) incorporate a
level warning feature to warn the user when
the fresh water level drops below 25% or when
the waste water level reaches 100%.
If the water pump power is turned on and
the fresh water level drops to below 25% a
warning beep will be heard and a message will
be displayed on the control panel. To cancel
the warning, press the select button.
If the water pump power is turned on and the
waste water level rises to full (100%) a warning
beep will be heard and a message will be
displayed on the control panel. To cancel the
warning, press the select button.
These warnings will not be repeated unless the
water pump power switch is turned off and on
again.
This is to ensure the warning does not become
a nuisance.
SWIFT COMMAND POWER CONTROL SYSTEM
Summary of Contents for Basecamp 2018
Page 1: ...Swift Group Owner s Handbook Basecamp Issued July 2017 CREATING SMILES FOR LIFE ...
Page 48: ...S E RVICE S 46 GAS SCHEMATIC Gas schematic Back to section menu ...
Page 141: ...MA INT E NA N CE 140 WIRING DIAGRAM ROAD LIGHTING Back to section menu ...
Page 142: ...MA INT E NA NCE 141 WIRING DIAGRAM CONSUMER CIRCUITS Back to section menu ...
Page 143: ...MA INT E NA N CE 142 WIRING DIAGRAM CONSUMER CIRCUITS ROOF Back to section menu ...
Page 144: ...MA INT E NA NCE 143 WIRING DIAGRAM POWER CIRCUITS Back to section menu ...
Page 145: ...MA INT E NA N CE 144 WIRING DIAGRAM 230V CIRCUITS Back to section menu ...
Page 146: ...MA INT E NA NCE 145 WIRING DIAGRAM 13 PIN SOCKET Back to section menu ...
Page 147: ...MA INT E NA N CE 146 WIRING DIAGRAM CABLE COLOUR CHART Back to section menu ...