NOTE: When external units are used for control of mains power, make sure that: 
 

  No dimmer packs are used. The machine must be supplied with no (off) or full (on) mains 

voltage. Starting and stopping the machine is ALWAYS done with DMX 512 or manual 
on/off by using the “OK” button. On/off cannot be controlled by switching the mains power 
on/off. 

 

  Fluctuating voltage or frequency will damage the machine. 

 

 

6.3 Fluids: 

 

All Swefog Ultimate machines have been developed and designed to work with Swefog 
Ultimate mineral-oil based fluids. If original fluid is used and regular maintenance is performed, 
the machine will work well for many years.  
Swefog Technology Group AB have not performed tests with the Ultimate hazers with any 
other fluids than the original types, therefore no guarantee can be issued regarding 
performance, health hazards, residues, component damage/wear outs or other disturbances 
or inconveniences related to non-original fluids.  
 
Many fluids may look the same at first sight, but the truth is that no fluids are identical. There is 
a significant risk of internal parts and materials being affected, especially parts made with 
plastics and rubber.  
Swefog original fluids are made with a special, medical-grade white mineral oil, with a viscosity 
especially developed to perform well with the small nozzles and low air pressure used in the 
Ultimate hazer series. The oils used during the manufacturing process are also filtered several 
times to ensure an extremely clean fluid. Swefog Ultimate fluids are of medical grade, which is 
the finest oil quality available. Medical grade oils, which is a quality grade far better than “food 
grade” or “technical grade”, is also used in manufacturing of medicals and similar processes 
with extremely high demands on purity & cleanliness. 
 
In a cracker hazer, like the Ultimate series, the oil fluid is processed, “cracked” to extremely 
small particles with the use of several spray nozzles. The haze is filtered and let out without 
any kinds of chemical changes, and made without the use of heat, which is the case in an 
ordinary smoke or haze machine

.

 This means, that the characteristics of the fluid used is 

VERY important for the end result, such as: haze quality, separation, loss/absorption of light 
illumination power, smell/odour, hang time, dew time, health hazards, exposure levels,  
exposure time limits for actors and personnel etc. 
 
Bear in mind, low-cost fluids will never give you the same performance and quality as the 
original product, the fluid your machine was designed to be used with. 
 
Swefog Ultimate 2000 DMX has an extremely low fluid consumption, only 0,05 litre (0,01 U.S. 
gal) per hour at continuous operation at full output. A 5L (1,3 U.S. gal) canister will last for 
approximately 80 hours of continuous operation at full output.  
 
Always use ORIGINAL fluid, to ensure the highest performance and a SAFE operation. 
Problems related to non-original fluids are NOT covered by Swefog’s 2-year warranty. 

 

Summary of Contents for Ultimate 2000DMX

Page 1: ...Swefog Ultimate 2000DMX 20 202 240 Ultimate 2000 DMX 230V 50Hz Rev 2 2012 12 02 OWNER S MANUAL ...

Page 2: ...avant l assemblage le montage et de faire fonctionner cet équipement WICHTIG Lesen Sie alle Warnungen sorgfältig bevor Sie das Gerät zusammenbauen installieren und benutzen IMPORTANTE Por favor lea todas las precaucionas y las advertencias antes de ensamblar montar y operar este equipo IMPORTANTI Leggere tutti gli avvertenti prima di montare e usare questo apparecchio ...

Page 3: ...inlet filter mats on machine housing 9 6 1 2 Ergonomic AluGrip handle 9 6 2 Control panel display 10 6 2 1 Normal operation 10 6 2 2 Control DMX 512 manual on off 11 6 3 Fluids 12 7 SERVICE MAINTENANCE REPAIR 13 8 SPECIFICATIONS 13 SWEFOG WORLDWIDE WARRANTY 14 Manufactured by S W E F O G T E C H N O L O G Y G R O U P AB INDUSTRIVÄGEN 15 SE 682 33 FILIPSTAD SWEDEN Tel 46 590 122 50 e mail info swef...

Page 4: ...ll find the following symbols CAUTION This symbol appears adjacent to caution messages Not heeding these messages could result in minor personal injury and or damage to equipment QUICK SETUP GUIDE 1 Read chapter 3 SAFETY PRECAUTIONS 2 Place machine on a level surface 3 Fill Swefog Ultimate haze fluid in the tank fill slowly and do NOT exceed the max level indicator 4 Connect to a mains outlet with...

Page 5: ...tenance can be downloaded from www swefog com Refer all service and repair work to qualified personnel This manual and updates can also be downloaded as PDF files from www swefog com 2 UNPACKING Swefog Ultimate 2000 DMX package contains One machine One manual Please note no mains cable is included and no fluid Save the box and packing material for future use If the machine needs to be transported ...

Page 6: ...als when it is ON If mains voltage input is regulated through a dimmer switch the compressor and other electric components will be damaged Service internal parts ONLY if you have the know how and experience to perform the service correctly If not please contact a Swefog service centre or the manufacturer NOTE Incorrect service and or use of non original spare parts will void the warranty NEVER cha...

Page 7: ...only Use only Swefog Ultimate fluid in this machine Use responsible concentrations of haze to create atmospheric effects Not for residential use Must be handled by qualified personnel at all times According to a report commissioned by Actors Equity Association and the League of American Theatres and Producers mineral oil should be used in such a manner that an Actors exposure does not exceed a pea...

Page 8: ...r electrical data 3 Fluid fill 4 Haze outlet 5 Fluid level indicator 6 Left side air inlet 7 Front side air inlet 8 Heavy duty rubber feet 9 Internal fan air inlet filter holder screws release both screws when replacing the filter mat 10 Internal fan air inlet filter frame 11 Control panel connectors ...

Page 9: ...t left right sides of machine housing the second mat covers the rear fan inlet Replacement of compressor s air inlet filter cartridge Cleaning of the compressed air filter cartridge Cleaning of the nozzle unit only necessary if haze output is low Cleaning or replacement of haze fluid filter If necessary empty and clean the fluid tank NOTE The filter mats are made with a special material that withs...

Page 10: ...VER fill fluid while machine is operating The machine is continuously cooled by several fans and an intercooler and can operate without interruption as long as there is mains power and fluid supply Operating the machine with an empty fluid tank does not damage the machine Connect a mains cable to a suitable mains outlet for 230V min 5 Amps capacity NOTE Due to the high starting current the machine...

Page 11: ...t be controlled with the DMX level only through the operating intervals The best way to control the machine without the risk of an unwanted start or stop and risk of damage to compressor motor is to set the level at 0 0 for off and 255 100 for on Tip The last selected address will be stored in the processor s memory when the machine is switched off and or mains voltage is disconnected The address ...

Page 12: ... The oils used during the manufacturing process are also filtered several times to ensure an extremely clean fluid Swefog Ultimate fluids are of medical grade which is the finest oil quality available Medical grade oils which is a quality grade far better than food grade or technical grade is also used in manufacturing of medicals and similar processes with extremely high demands on purity cleanli...

Page 13: ...lified technical personnel or contact a preferred Swefog dealer Preferred dealers have qualified service technicians and will be able to perform most service works 8 SPECIFICATIONS Type Cracker haze generator pneumatic Fluid type Mineral oil based Operation Continuous Fluid consumption Approximately 0 05 litre 0 01 US gal per hour Fluid reservoir capacity 2 5 litre 0 66 US gal Cracker nozzle type ...

Page 14: ...xtures or other spare parts shipped in non factory shipping cartons and packing materials Limited Warranty Unless otherwise stated Swefog products are covered by a two year parts and labour limited warranty Guarantee will be invalid if the Swefog machines have been used with non original fluids It is the owner s responsibility to furnish receipts or invoices for verification of purchase date and d...

Reviews: