AMU-II Interface Options

Installation of the Interface Option

3

To install an interface option, proceed as follows:

1

Switch power off.

2

Loosen the four screws at the back of the AMU-II transmitter and 

remove the backplate.

3

Pull the mainboard [B] completely out of the housing.

4

Plug the interface option onto the pins [D] on the mainboard.

5

Reinsert the mainboard into the housing, making sure to insert 

both boards into the correct guide grooves.

6

Carefully press the mainboard [B] against the display board [C] 

until it snaps into place.

Connector

Field

7

Remove the cover [F] from the connector field.

8

Apply the supplied sticker [G], [H] or [I] to the connector field.

9

Reinstall the backplate [E] onto the housing.

Mainboard:

Interface option:

Fourth guide groove from the bottom

First guide groove from the right

E

F

Backplate

Covered connector field 

(condition at delivery)

G

H

I

Labeling for USB option

Labeling for RS485 option

Labeling for HART option

9 10

L/+ N/-

11 12131415 16

17 18 19 20 21

1 2 3 4 5 6 7 8

COM

F

E

G

H

I

Summary of Contents for AMU-II

Page 1: ...AMU II Interface Options A 81 460 010 A 81 460 020 A 81 460 030 Installation Instruction 110820 290421...

Page 2: ...f the Interface Option WARNING Electrical shock hazard Before opening the housing disconnect the AMU II transmitter from the power supply CAUTION Observe precautions for handling electrostatic dischar...

Page 3: ...ert both boards into the correct guide grooves 6 Carefully press the mainboard B against the display board C until it snaps into place Connector Field 7 Remove the cover F from the connector field 8 A...

Page 4: ...ile is completed the next time the USB stick is inserted a new file will be created the USB stick is deactivated and can be removed Pushbutton Pressing the pushbutton J has the same effect as calling...

Page 5: ...trument operation configuration of signal outputs and re lays etc 2 Download logger message list and cal history Start upload 1 Copy all files you need aout a37 hex to the root directory of the USB st...

Page 6: ...ngs for Modbus RTU Settings for Profibus Terminating resistor On the last RS485 interface in the network move the switch to the position marked Ron to activate the terminating resistor Interface Descr...

Page 7: ...following menu items become visible Installation Signal Outputs Signal Output 3 Installation Interface Device Address Field Device Description The HART 7 x Field Device Specification can be downloade...

Page 8: ...r W ast e t W a e r E f u e n t s P o o l S a n i t a r y Swan Analytical Instruments CH 8340 Hinwil www swan ch swan swan ch Swan Products Analytical Instruments for Swan is represented worldwide by...