Maintenance
Maintenance
•
WARNING
Switch off the tool and remove the plug from the
power outlet or take out the removable battery
before changing tooling, performing maintenance, or
transporting the tool
When cleaning the tube facing tool, clear the collet set and tool
body of debris and dirt.
When changing the cutting insert, clean the tool holder and
inspect it for damage.
Breakaway Nut Replacement
Note: The ordering number for a replacement TF48 breakaway
nut is MS-TF48-NUT-SQ.
1. Verify the tool is unplugged or remove the battery.
2. Loosen the M5 ×
16 set screw using the provided 4 mm hex
key.
3. Remove the collet housing half of the tool.
4. Remove the breakaway nut using a 15 mm wrench.
5. Install the new breakaway nut. Securely tighten the
breakaway nut to the motor shaft.
6. Replace the collet housing half and tighten the M5 × 16 set
screw.
7. For cordless models, replace the battery.
Fig 28 Loosening the Set Screw
Fig 29 Removing the Collet Housing
Half of Tool
Fig 30 Removing the Breakaway Nut
Fig 31 Breakaway Nut Removed from